41
16.
On the screen as shown in
, select
View Associated Drives
and press
Enter
. You
can view the detailed information about the RAID array, including name, level, and drive
information.
Figure 70 Selecting View Associated Drives
Configuring hot spare drives
For data security purposes, configure hot spare drives after configuring a RAID array. You can
configure global hot spare drives or dedicated hot spare drives.
NOTE:
•
A hot spare drive can be used only for RAID levels with redundancy.
•
The capacity of a hot spare drive must be equal to or greater than the capacity of the smallest
drive in the RAID array.
•
Only the drive in
Unconfigured Good
state can be configured as a hot spare drive.
Configuring a global hot spare drive
1.
On the storage controller configuration screen as shown in
, select
Drive
Management
and press
Enter
.
Summary of Contents for UniServer R4300 G6
Page 36: ...21 Figure 23 Selecting the controller and RAID level 4 Select drives and then click Next...
Page 40: ...25 Figure 27 Selecting the RAID array to be deleted 2 In the dialog box that opens click Yes...
Page 66: ...24 Figure 37 Confirming RAID creation 7 Click OK to complete the RAID creation...
Page 164: ...89 Figure 158 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 321: ...90 Figure 138 Configure Controller Settings screen for the RAID P460 B2...
Page 469: ...19 Examples Viewing physical drive informatoin Syntax mnv_cli info o pd Examples...
Page 513: ...7 Figure 10 Selecting Drive Management 4 Select the target drive and then press Enter...
Page 514: ...8 Figure 11 Select the target drive 5 View the value of the Status field...
Page 529: ...23 Figure 33 Identifying a storage controller 2...