18
TLC 2100
271-0498-4852503#
Digital Display
{Continued}
TAPE END
Lights when the end of the tape is reached during RECORD mode.
When TAPE END indicator is lit, the tape must be ejected in order to turn off the
TAPE END indicator in the display.
Will NOT light when RE-REC, EVEN IF ALARM has been selected in the "ALARM
RECORD OPTIONS" menu (see page 27).
OR
Will NOT light if an alarm recording has not been made and RECYCLE, STOP IF
ALARM was selected from the "ALARM RECORD OPTIONS" menu.
TIMER INDICATOR
Lights during Timer recording.
Flashes whenTimer mode is entered and one or more of the following conditions
exists:
• A cassette is not loaded.
• A cassette without a safety tab is loaded.
• The Timer has not been programmed.
LOCK INDICATOR
Lights when the recorder is in the Security Lock mode. All front panel controls are
disabled when lock indicator is lit.
B, R
B or R will light when a Brown (+azimuth) head or Red (-azimuth) head mode is
selected in the System Options submenu.
DIGITAL COUNTER (0000)
Shows the tape time counter. Each digit incremented represents 1 second of time
in 2 hour speed. If the counter is reset to 0000 at beginning of tape, a T120 cassette
will increment the counter to approximately 7200 at end of tape. In modes other
than RECORD, the counter will increment or decrement only where a recording
was made, i.e., when going over a section of blank tape, the counter will not
change.
TAPE SPEED INDICATOR (000), SPEED ANNUNCIATOR
Displays the selectected Tape Speed. The Speed annunciator will light in conjunc-
tion with the Tape Speed Indicator.