Günter & Hauer
8
(Grounding) - yellow-green wire
Replace the power cord only at a service center or with qualified personnel.
If it is necessary to replace the power cord, use a cord type H05VV-F or
H05RR-F with a cross section of 3X0.75 mm2 in accordance with current regulations.
The connection to the terminal box should be made as shown in the figure above.
READJUSTMENT TO OTHER TYPES OF GAS (NOT ALL MODELS)
Replacement of nozzles
1. Remove the grilles.
2. Remove the burner caps and covers.
3. Using a size 7 socket wrench, unscrew and
remove the injectors as shown in the figure,
replace them with nozzles that are suitable for the
type of working gas.
4. Assemble the parts back by following the steps
in reverse order.
If the pressure of the gas used differs from the
provided one, the appropriate gas pressure
regulator must be installed on the inlet pipeline,
which corresponds to the norms in force in the
country where product is used.
After replacing the nozzles, it is necessary to
adjust the flame level.
MINIMUM FLAME ADJUSTMENT
To adjust the minimum level, follow these steps:
1. Light a fire in the burner following the
instructions above.
2. Set the tap to the minimum flame position.
3. Pull out the handles.
4. Adjust the bypass valve (bypass screw) shown in the figure with a slotted
screwdriver.