Gunter & Hauer GH 43 CI Instruction Manual Download Page 8

Günter & Hauer 

ELECTRICAL CONNECTION 

For operation of this gas hob it is necessary to provide power supply from a single-phase 
electric network with voltage of 220 ~ 230 V. Connection has to be executed according 
to norms and according to current legislation. Before connecting, make sure that: 

• the electrical network has a proper grounding in accordance with current regulations;

• After installing the appliance, easy access to the mains socket or multi-pole switch is
provided.

The hob is completed with a power cord and a plug. Connect it to a suitable grounded 
socket. 

If the appliance is permanently connected to the 
mains,  it  is  necessary  to  install  a  multipole 
switch  between  them  with  a  distance  between 
open contacts of at least 3 mm, the type of which 
according to the current rules corresponds to the 
required load. 

The  switch  must  not  open  yellow  /  green 
grounding  cable.  The  brown  phase  cable 
(coming  from  terminal  "L"  of  the  terminal 
block)  must  be  connected  to  the  phase  of  the 
power supply network. 

The  mains  cord  must  be  placed  in  such a  way 
that no part of it can be heated above 75 ° C. 

An example of the optimal cord laying is shown 
in the figure on the left. When laying the cord, 
secure it to the side of the furniture with clamps 
to  avoid  contact  with  the  equipment  installed 
under the hob. 

L (phase) – brown 
cabel 

N (zero) – blue cabel 

C – power cord 

BACK VIEW 

FRONT VIEW 

clamps 

Working 

hole in 

the 

furniture 

Rigid copper pipe or 
stainless-steel hose 

Summary of Contents for GH 43 CI

Page 1: ...G nter Hauer INSTRUCTION MANUAL Built in Gas Hob GH 43 CI GH 643 IVR GL 643 IVR GL 641 TN GL 641 WTN GL 745...

Page 2: ...G nter Hauer CONTENT PRECAUTIONS 2 USE OF GAS BURNERS 4 CONNECTION 6 INSTALLATION 9 HOB OPERATION 12 CLEANING 15 SPECIFICATIONS 17...

Page 3: ...cal allow to use it in safe conditions without supervision or without instructions of the responsible person who ensures proper use of the device All installations adjustments and readjustments to the...

Page 4: ...ired contact the nearest authorized service centre which is supposed to use original spare parts Unauthorized change of characteristics of this product or introduction of any changes in its design may...

Page 5: ...e burner and turn it counterclockwise to the Max heat symbol This position also corresponds to the Ignition symbol When you press the control knob in this position sparks are formed the ignition will...

Page 6: ...raise the fire to the burner press the corresponding knob and turn it counterclockwise to the maximum position When the power supply is applied after the hob is installed or switched off it is normal...

Page 7: ...t is possible to make a fixed connection or use a flexible stainless steel hose When using flexible metal hoses be careful that they do not touch moving parts or they do not get crushed Take the same...

Page 8: ...is necessary to install a multipole switch between them with a distance between open contacts of at least 3 mm the type of which according to the current rules corresponds to the required load The sw...

Page 9: ...tors as shown in the figure replace them with nozzles that are suitable for the type of working gas 4 Assemble the parts back by following the steps in reverse order If the pressure of the gas used di...

Page 10: ...y to obtain a small homogeneous and uniform ring of the burner flame as a result 5 Finally check that when the tap is quickly turned from the position of the maximum flame to the position of the minim...

Page 11: ...ary to prepare an aperture for embedding according to the sizes specified in drawing thus it is necessary to provide that distance between edge of the device and the nearest wall was not less than 50...

Page 12: ...he appliance If the hob is installed together with the oven precautions should be taken to ensure that safety rules are observed Special attention should be paid to ensure that the power cord and gas...

Page 13: ...mbustion product removal system must be provided in the room where the hob is installed This can be either a hood or a fan on the window or vent which is switched on when using the appliance The room...

Page 14: ...ttom of the pan see the following table BURNERS SCHEME GH 43 CI GH 643 IVR GL 643 IVR 1 Semi Rapid 1750 W 2 Semi Rapid 1750 W 3 Auxiliary 1000 W 4 Rapid 3000 W 3300 W 3300 W GL 641 TN GL 641 WTN 1 Tri...

Page 15: ...uxiliary 10 14 Semi Rapid 16 18 Rapid 20 22 Triple 24 26 As soon as the liquid in the pan starts to boil reduce the flame to the minimum needed to keep it simmering Use only pans and flat bottomed fry...

Page 16: ...ured Cooking utensils should not be in the control area of the hob Do not use aerosols near a working hob Before removing the pan reduce the flame power or turn off the burner Make sure that the pan h...

Page 17: ...mic and metal electrodes Keep these parts clean to prevent ignition difficulties and make sure that the holes in the burner flame cutter are not clogged Constantly check the cleanliness of the safety...

Page 18: ...Type of gas and pressure Gas usage Nozzle diameter Efficiency Valve bypass diameter Name mBar g h l h 1 100mm MIN MAX 1 100 mm 1 Rapid G30 butane 28 30 mBar G31 propane 37 mBar G20 natural 20 mBar G20...

Page 19: ...cannot be transferred to another user This appliance complies with EU Directive 2002 96 CE A special sign depicting a crossed out wheeled bin means that this appliance must be disposed of separately...

Reviews: