Keep the area near the flame openings under the hood very clean. Clean the holes of
the burner nozzles using only copper wire. Do not use steel wire or open holes.
PERIODIC TECHNICAL INSPECTION
In addition to the usual care of the hob you need to:
• Perform periodic technical control of the controlling elements of the hob and its
working units. After the expiration of the warranty period at least once every two years
it is necessary to contact the service center in order to conduct a technical inspection of
the hob;
• Eliminate detected problems; and
• Carry out periodic care of working knots of the hob.
SPECIFICATIONS
Burners
Type of gas and
pressure
Gas usage
Nozzle
diameter
Efficiency
Valve bypass
diameter
№
Name
mBar
g/h
l/h
1/100mm
MIN
MAX
1/100 mm
1
Rapid
G30 (butane) 28-30 mBar
G31 (propane) 37 mBar
G20 (natural) 20 mBar
G20 (natural) 13 mBar
218
214
-
286
286
85
85
115-Y
131
0,75
0,75
0,75
0,75
3
3
3
3
42
Adjustable
2
Semi-
Rapid
G30 (butane) 28-30 mBar
G31 (propane) 37 mBar
G20 (natural) 20 mBar
G20 (natural) 13 mBar
127
125
-
167
167
65
65
97-Z
112
0,55
0,55
0,55
0,55
1,75
1,75
1,75
1,75
34
Adjustable
3
Auxiliary
G30 (butane) 28-30 mBar
G31 (propane) 37 mBar
G20 (natural) 20 mBar
G20 (natural) 13 mBar
73
71
-
95
95
50
50
72-X
72
0,35
0,35
0,35
0,35
1
1
1
1
27
Adjustable
4
Triple*
G30 (butane) 28-30 mBar
G31 (propane) 37 mBar
G20 (natural) 20 mBar
G20 (natural) 13 mBar
255
250
-
333
333
95
96
130-K
150
1,6
1,6
1,6
1,6
3,5
3,5
3,5
3,5
73
Adjustable
*Triple burner is available on GH41C