Günter & Hauer
9
• If the 20 mbar / 13 mbar methane appliance is readjusted to liquefied gas, screw the
bypass valve clockwise as far as it will go.
• If the liquefied gas appliance is set to methane at a pressure of 20 mbar, unscrew the
bypass valve by about 1/4 turn.
• When adjusting a methane-operated appliance with a pressure of 20 mbar, on methane
with a pressure of 13 bar, unscrew the bypass valve about 1/4 turn.
• If the liquefied gas appliance is set to methane at a pressure of 13 mbar, unscrew the
bypass valve by about 3/4 turn.
• In any case, it is necessary to obtain a small homogeneous and uniform ring of the
burner flame as a result.
5. Finally, check that when the tap is quickly turned from the position of the maximum
flame to the position of the minimum flame, the fire in the burner does not go out.
The adjustment described above can be easily performed regardless of the location or
mounting of the hob in the kitchen furniture.
INSTALLATION
This hob is intended for installation in the furniture steady against influence of high
temperatures. The walls of the furniture must withstand a temperature of at least 75 °C
plus ambient temperature in accordance with European standards.
Avoid installing the appliance near flammable materials such as curtains, etc.
Bypass valve for regulating
the minimum mode