Windsor 500 Programming Manual - Issue C
- 98 -
Set/Uns Opts
Log/Set
Normally an area alarm log is not accessible when the area is set. If the Log/Set option is on
then an area alarm log can be accessed while the area is still set.
Set/Uns Opts
SetFailSndr
Normally, when an area fails to set, the internal sounder and keypad bleepers will be turned
on. If the Set Fail Sounder option is on then the external sounder will also be turned on.
Set/Uns Opts
Log Areas
Normally when logging an event for all areas the event will only be logged in the system log. If
the Log Areas option is on then the event will be stored in each individual area log. This option
only applies to logging set, unset, reset and late working. This option must on if you need to
signal set and unsets with individual area IDs.