Windsor 500 Programming Manual - Issue C
- 90 -
3. A single open/close/set action per day with temporary late working.
6:00 7:00 08:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00
Open
Close
Set
Unset
Set 1
Set 2 (late)
Set Time extendible
(if User Edit is on)
Program Open 1, Close 1, Set 1 and Set 2.
4. Two open/close/set actions per day (Note that no late working is possible).
6:00 7:00 08:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00
Open 1
Close
Open 2
Close
Unset
Set 1
Unset
Set 2
Set Time extendible
Set Time extendible
(if User Edit is on)
(if User Edit is on)
Program Open 1, Close 1, Open 2, Close 2, Set 1 and Set 2.
EvProg Schedule Menu
Schedule Times - HS
The times for each day can be programmed. If a function is not required then enter a time of
00:00. If the day is to be omitted then enter a time of 00:00 for all times.
Some user types (see user authorised functions) can view the times. The panel can also be
programmed to allow a users to edit the times. To edit a time press
↵
when the current value
is on display.
1=Shunt On
There are 8 HS event programmer times.
2=Open 1
3=Close 1
4=Set 1
5=Open 2
6=Close 2
7=Set 2
8=Shunt Off
EvProg Schedule Menu
Shunt On
An HS event programmer can be programmed to automatically shunt (bypass) all circuits in
the programmed shunt group at the shunt on time.
Mon Shunt On
00:00
Time of day
All circuit shunt operations are recorded in the event log. All shunted circuits will remain
shunted until the shunt off time unless the area is not unset during the open/close period. If
the area is not unset by the programmed close 1 time the shunt will be removed.