Windsor 500 Programming Manual - Issue C
- 76 -
TX menu
System
0=Tamper
The system tamper.
1=Tam.Uns
Unset Tamper
2=Verify Alm
Verified alarm
3=230vFlt
Mains fault.
4=Eng On
Engineer on site.
5=L.Vlts
Low supply voltage.
6=Line Fault
Line fault.
7=Comm Tst
Communicator test output (on for 3 seconds only)
8=Comm OK
Comms OK (on for 5 seconds)
9=230vOK
Mains restored
0=P.Fail
Supply voltage is at the power fail threshold.
1=Pow.On
Power restored (on for 10 seconds only).
2=UI Fire
Keypad fire panic
3=UI Med.
Keypad medical panic
4=UI PA
keypad PA
5=Set
System is set
6=Battery Test
Battery Test fail
7=Rem.Alm
Remote authentication alarm.
8=Daily
No activity on device in previous 24hrs (on for 10 seconds only).
9=Alarm Abort
On for 3 seconds if a user aborts an alarm transmission.
TX menu
Area
0=Set
Area set.
1=Unset
Area unset.
2=Duress
Duress code entered.
3=Ent Alm
Entry route alarm.
4=Auto Rst
Auto reset fail.
5=Bypass
Area circuit(s) bypassed.
6=Call Eng
Engineer reset is required.
7=Log On
A user is logged on an area keypad.
8=Set Ack
Set acknowledge
9=Power Rst
Fire/viper power output -function same as concentrator output option
0=A.Set Flt
Event programmer auto set with fault/auto set fail.
1=Shnt Flt
Event programmer only, shunted circuit in alarm when shunt removed.
2=Set Warning
Event programmer only, area schedule in the set warning period.
3=EVP Open
Event programmer only, area schedule in open/close time window.
4=Ready
Area is ready to set (no NA circuits in alarm).
5=Set Alm
Common intruder output for all set alarms.
6=Unset Alm
Common intruder output for all unset alarms.
7=Sounder
Output follows the area sounder.
8=Audio
Output follows the area audio (on/off only).
9=Strobe
Output follows the area strobe.
For each of the programmable system and area functions a TX channel and device number
may be specified. For example if tamper is selected you will see the following display.
Sys Tamper
TX-0 Dev-01
0-8,00-19