English (GB)
60
8.5.31
Configuration of tank volume
In this menu, the tank volume and degassing fans can be
configured.
Fig. 67
Configuration of tank volume
To change a value, push the respective square. Active values are
highlighted in green.
To save the settings, push [
].
To revert to the previous menu, push [
].
For details on general menu symbols see section
.
8.5.32
Configuration of interface
In this menu, the interface can be configured.
Fig. 68
Configuration of interface
Only one option can be chosen in this menu at a time.
To change a value, push the respective square. Active values are
highlighted in green.
To save the settings, push [
].
To revert to the previous menu, push [
].
For details on general menu symbols see section
Menu action
Required user level
Access menu
4
Administrators
Change settings
4
Administrators
ID 0
112
Display text
Description
Tank volume
This setting must comply with the actual tank
volume of the degassing and storage tank.
No. of fans
Number of degassing fans installed on the
degassing and storage tank.
Automatic
changeover at
If two degassing fans are used, the cause for a
changeover from the duty fan to the standby
fan and vice versa can be defined here.
•
Start & fault
The system changes over every time
production is started and after a fault.
•
Fault
The system changes over after a fault.
•
never
The system does not change over
automatically.
Menu action
Required user level
Access menu
3
Commissioning staff
Change settings
3
Commissioning staff
ID
01
13
Display text
Description
no
Interface/Com
munication
Choose this setting to control the Selcoperm
electrolyser via the parallel port.
Profinet
Profinet communication
•
I/O Device
Standard setting. The Selcoperm touchscreen
is used for input and output of values.
•
Put/Get
Choose this setting to control the Selcoperm
electrolyser via an S7 connection with "Put"
and "Get" commands.