English (GB)
28
5.3.2 Technical data for water-cooled rectifier
Fig. 21
Example of water-cooled rectifier
5.4 DC cable set
* The cable is delivered in one piece of 40 m.
The number of cable sets required depends on the type of the
Selcoperm electrolyser.
Enclosure class:
IP20
Max. relative humidity
(non-condensing):
75 %
Permissible ambient temperature for
operation (min. / max.):
+10 / +40 °C
TM
06
22
20
05
15
SES type
Dimensions
L x W x H
[mm]
Weight
[t]
DC
current
[A]
Power loss
[kW]
Cooling water flow
(at inlet temp. 20 °C)
[l/h]
Input voltage
50 Hz
3 PE
[VAC]
Current per
phase
[A]
SES-5000
1250 x 875 x 2200
0.9
1 x 800
4
400
380
56.8
400
54.0
415
52.0
SES-7500
1250 x 875 x 2200
0.9
1 x 800
4.5
400
380
80.8
400
76.8
415
74.0
SES-10000
1250 x 875 x 2200
1.0
1 x 800
5.01
400
380
106.7
400
101.3
415
97.7
SES-15000
1250 x 875 x 2200
1.1
1 x 800
5.67
400
380
154.8
400
147.1
415
141.8
SES-20000
1900 x 875 x 2200
1.9
2 x 800
10.03
800
380
213.5
400
202.8
415
195.5
SES-30000
2500 x 875 x 2200
2.2
2 x 800
11.33
800
380
309.8
400
294.3
415
283.7
SES-45000
3400 x 875 x 2200
3.2
3 x 800
17
1200
380
464.6
400
441.4
415
425.4
Number of
cables*
Max. length*
[m]
Cable cross-section
[mm
2
]
2 x 2
10
240
SES type
Number of cable sets required
SES-5000
SES-7500
SES-10000
SES-15000
1
SES-20000
SES-30000
2
SES-45000
3