English (GB)
17
4.2.4 Overview hydraulics SES-5000 to SES-15000
Fig. 10
Overview hydraulics SES-5000 to SES-15000
* Only available in SES-10000 and SES-15000.
T
M
06
22
42
49
15
V0.09
1
X
V0.05
1.10
1.11
V0.10
0.05
0.01
0.02
V0.04
V1.01
V0.02
V0.01
C
V0.07
V0.08
Y
Z
A
1.09
0.03
V
1.03
1.02
1.04
1
1.01
B
V1.02
V0.06
GND3
C1.1
C1.2
Pos.
Description
Pos.
Description
0.01
Level switch in collecting tray
GND3 Earth connection of electrolyte
0.02
Water inlet flow sensor
V
NaClO solution outlet
0.03
NaClO outlet temperature sensor
V0.01
Water inlet valve
0.05
Water inlet solenoid valve
V0.02
Pressure reducing valve
1
Protection against accidental contact
V0.04
Non-return valve
1.01
Temperature sensor (DC+)
V0.05
Static mixer
1.02
Temperature sensor (DC-)
V0.06
Electrolyte sample valve
1.03
Temperature sensor (DC+)
V0.07
Acid inlet and outlet valve
1.04
Temperature sensor (DC-)
V0.08
Drain outlet valve
1.09
Cell outlet level switch
V0.09
NaClO sample valve
1.10
Cell inlet flow sensor
V0.10
Brine inlet valve
1.11
Cell inlet temperature sensor
V1.01
Cell inlet adjusting valve
A
Soft water inlet
V1.02
3-way ball valve
B
Brine inlet
X
NaClO sample outlet
C
Acid cleaning inlet and outlet
Y
Electrolyte sample outlet
C1.1
Electrolysis cell 1
Z
Drain outlet
C1.2
Electrolysis cell 2*