5.2.4 Setpoints
The following table shows typical values expected upon commissioning. Please note that these values may need to be adjusted due to
salt and water quality on site.
* The brine flow can be different, depending on the saturated brine concentration. It is important to adjust the right salinity.
** The voltage can be different, depending on the water temperature and the brine temperature.
5.2.5 Approvals
The Selcoperm system is certified according to CE and EAC.
5.2.6 Materials
No. Setpoint
SES-
5000
7500
10000
15000
20000
30000
45000
1
Capacity
[g/h]
5000
7500
10000
15000
20000
30000
45000
2
Water inlet pressure (into unit)
[bar]
3-4
3-4
3-4
3.5-5
3-4
4-5
4-5
3
Adjusted water pressure (at pressure
reducing valve V0.02)
[bar]
1.5 - 2
1.5 - 2
2 - 2.5
3.5 - 4
2.5 - 3
3 - 3.5
3.5 - 4
4
Soft water flow
[l/h]
570 +15 850 +15 1140 +20
1700 +25
2280 +40
3400 +50
5100 +75
5
Brine flow*
[l/h]
63
94
126
187
252
376
560
6
Max. capacity brine pump
[l/h]
100
130
150
250
350
450
650
7
Total sodium hypochlorite solution flow
[l/h]
633
944
1266
1887
2532
3776
5660
8
Water temperature
[°C]
10-20
10-20
10-20
10-20
10-20
10-20
10-20
9
Conductivity of electrolyte
[mS/cm]
44-46
44-46
44-46
44-46
44-46
44-46
44-46
10
Amperage
[A]
780
780
780
780
780
780
780
11
Voltage**
[V]
27-32
42-49
54-63
84-94
54-63
84-94
84-94
12
Sodium hypochlorite solution strength
[g/l]
8
8
8
8
8
8
8
13
Exhaust air flow
[m
3
/h]
300
450
600
900
1200
1800
2700
14
Specific gravity of electrolyte
[g/ml]
1.02 -
1.022
1.02 -
1.022
1.02 -
1.022
1.02 -
1.022
1.02 -
1.022
1.02 -
1.022
1.02 -
1.022
System frame
PE-HD
Housing cover
Powder coated steel
Electrolysis chamber cover
Polycarbonate
Electrolysis cell tube
PVC-U clear
Electrolyser parts
PVC-U grey
Electrodes
Titanium / Titanium coated
Electrical connections
Copper
Internal pipes / fittings
PVC-U grey
Seals
EPDM
Pump dosing heads
PVC-U grey