English (GB)
36
6.3 Dismantling and reassembling the Selcoperm
electrolyser housing
This section describes only the dismantling and reassembling of
the parts that must be removed for the electrical and hydraulic
installation.
The brackets and panels are hooked into the frame. Some are
fixed with fixing screws. After removing the fixing screws, the
parts can be removed by slightly lifting them.
Fig. 27
Housing SES-5000 to SES-15000
Fig. 28
Housing SES-20000 to SES-45000
Dismantling
Remove the parts in the following order.
SES 5000-15000:
• (60), (110), (90), (100), (10), (40).
SES 15000-45000:
• (60), (110), (90), (100), (10), (40), (20), (30), (46).
Reassembling
Reassemble the parts in the following order.
SES 5000-15000:
• (10), (40), (100), (90), (110), (60)
SES 15000-45000:
• (46), (20), (30), (10), (40), (100), (90), (110), (60).