Fault
44 | 74
BA_
T
D
3-
BM
001e
n_
01
4_D
e
lta-
p.
docx
Control unit GENO-IONO-matic
3
Fault
Explanation
Remedy
Er 0
Power failure > 5 minutes has
occurred.
The
signal
of a power failure is
not activated
in the
GENO-IONO-matic
3
ex-works
.
If the exchangers in operation
have been subjected to further
stress during the power failure, the
affected exchangers should be
regenerated by initiating a
regeneration manually (refer to
chapter 7.3).
Contact Grünbeck's technical
service-/authorised service
company. A different parameter
setting could be required.
Er 1
Run-time monitoring motor
regeneration valve has responded.
Connection cable from the
regeneration valve to the control
unit is incorrectly connected or
defective.
Microswitch S3 ... S5 defective.
Motor of the regeneration valve
defective.
Control unit defective.
Notify Grünbeck's technical
service-/authorised service
company.
Fuse F2 has tripped.
Replace fuse with the same type
(refer to chapter 13.3).
Pressure reducer on regeneration
valve set incorrectly (completely
open).
Notify Grünbeck’s technical
service-/authorised service
company.
Er 2
Run-time monitoring
motor-Transfer valve has been
activated.
Transfer valve-control unit
connection cable incorrectly
connected or defective.
Microswitch S1 ... S2 defective.
Motor transfer valve defective.
Control unit defective.
Call Grünbeck's technical service/
authorised service company.
Fuse F2 has tripped.
Replace fuse with the same type
(refer to chapter 13.3).
Summary of Contents for Delta-p
Page 1: ...We understand water Softening Water softener Delta p Operation manual ...
Page 57: ...Mounting instructions 57 74 BA_TD3 BM001en_014_Delta p docx ...
Page 58: ...Mounting instructions 58 74 BA_TD3 BM001en_014_Delta p docx ...
Page 59: ...Mounting instructions 59 74 BA_TD3 BM001en_014_Delta p docx ...
Page 60: ...Mounting instructions 60 74 BA_TD3 BM001en_014_Delta p docx ...
Page 62: ...Mounting instructions 62 74 BA_TD3 BM001en_014_Delta p docx ...
Page 72: ......