13.3
Overview of electrical cable connection
Electrical cable connection GENO-IONO-matic
3
Terminal
Function
Wire colour/wire number
Comments
Supply
Power supply from
transformer on rear of
housing.
Transformer fuse primary
0.25 A slow-blow.
45/46
9 V~
3/4
Power supply control
logic/chlorine cell
fuse F1 3.15 A slow blow.
47/48
24 V~
5/6
Encoder voltages
12 V= / 24 V= / 24 V~ fuse
F2 0.63 A slow-blow
49
PE
green-yellow
Earth wire
Voltage-free contacts
Contact rating max.
230 V~ / 1 A.
37/38/39
Signal contact: Normally
open contact opens when a
signal occurs.
Maintenance interval, pre-
alarm lack of salt- (Er A),
connection error to the
optional Profibus-module
(Er F).
39/40/41
Fault signal contact: Normally
open contact opens when a
fault occurs.
42/43/44
Relay function programmable
via Extended programming
menu level code 113.
Regeneration
Regeneration valve (R)
20
Micro-switch
green
+24 V= encoder voltage
21
Brown
Switch S3 (inside)
22
White
Switch S4 (centre)
23
yellow
Switch S5 (outside)
24
Motor 24 V~
grey
Motor wires black
Summary of Contents for Delta-p
Page 1: ...We understand water Softening Water softener Delta p Operation manual ...
Page 57: ...Mounting instructions 57 74 BA_TD3 BM001en_014_Delta p docx ...
Page 58: ...Mounting instructions 58 74 BA_TD3 BM001en_014_Delta p docx ...
Page 59: ...Mounting instructions 59 74 BA_TD3 BM001en_014_Delta p docx ...
Page 60: ...Mounting instructions 60 74 BA_TD3 BM001en_014_Delta p docx ...
Page 62: ...Mounting instructions 62 74 BA_TD3 BM001en_014_Delta p docx ...
Page 72: ......