Installation
27 | 74
BA_
T
D
3-
BM
001e
n_
01
4_D
el
ta-
p.docx
5.3
Installing the product
In order for the water pipe to be properly connected to the protective-equipotential bonding
on both sides of the product, we recommend establishing a corresponding electrical bypass
according to DIN VDE 0100-540.
No.
Designation
No.
Designation
1
Drinking water filter
2
Connection set
The water softener Delta-p is installed in the water pipe in accordance with DIN EN 806-2
and DIN 1988-200.
Please observe:
● The nominal connection diameter and connection size.
● Installation in horizontal orientation.
● The designation of the flow direction
on the housing must correspond to the flow
direction on site.
● Stress-free installation.
● Free outlet and discharge of the backwash water without back-pressure.