Flow chart details – overview adjustment
Lubricus Controller can be adjusted without any Lubricus unit attached. Settings will stay in memory. The Controller controls
the Lubricus units in sequence starting at exit 1.
.
1.
1)
1.1. For every Lubricus connected the number of outlets must be programmed.
Divided into left half (green LED) and to right (orange LED) half of the Lubricus body.
The display shows following: Base setting: A00 = no exit activated
A01 = 1 exit activated
A02 = 2 exits activated
Settings for every specific Lubricus Models
Type LUB-C-1
adjustment at green LED / left Lubricus body: 1 exit = A01
adjustment at orange LED / right Lubricus body no exit = A00
Type LUB-C-2
adjustment at green LED / left Lubricus body 2 exits = A02
adjustment at orange LED / right Lubricus body no exit = A00
Left side of Lubricus body: dispensing equal quantity from both exits/outlets.
green LED: Function left side of Lubricus body
orange LED: Function right side of Lubricus body
Normal Status Indication:
F: red LED – constant light – failure, fault, error report
OK: green LED – constant light – OK