Gruetzner Lubricus LUB-C-1 User Manual Download Page 5

                                                                    

 

 

page 5 

 

 

Attention

 

General safety details 

 

Everybody  who  is  involved  with  the  installation,  start-up,  maintenance  and  operation  of  the  Lubricus  Lubrication  System  
must read these instructions carefully! 

Use in accordance with guide

 

Lubricus Lubrication System is 

only

 allowed for 

industrial use

Lubricus Lubrication System may only be put into service, if it is integrated or attached to another 

machine and will be operated together with that machine. 
Lubricus  Lubrication  System  may  only  be  used  according  to  the  technical  data  (see  chapter 
“technical data”). 

Unauthorized 

structural changes

 at the Lubricus Lubrication System are 

not permitted

. We do 

not assume liability for damages of persons or machines which result from that. 

 

 

     Other uses or uses beyond those described above cannot be considered to be in   
     accordance with the regulations. 

Extent of warranty

 

Warranties concerning operating safety, reliability and capacity, are only granted under the following conditions: 
Assembly, installation, maintenance and repair are only carried out through trained specialist. Hazardous hot or cold 
machine parts must be shielded to prevent touching.  

Lubricus Lubrication System must be used according to the instructions in the technical operating manual 
- the rated technical data must not be exceeded in any case. 

- Retrofitting and repair work on the Lubricus Lubrication System may only be done by manufacturer. 

 

Liability and extent of guarantee

  

 

 

 

 

 

 

 

 

Proper functioning of the Lubricus Lubrication System can only be achieved through use of recommended lubricants from the 

original Lubricus range of accessories

, and by observation of all installation, operation and maintenance instructions.  

Grützner GmbH excludes all liability if these instructions are not observed.    
 
Grützner  GmbH  grants  guarantees  concerning  operating  safety,  reliability  and  performance  only  under  the  following 

conditions: 

 

assembly, installation, maintenance and repairs are carried out by qualified staff only; 

 

hazardous hot or cold machine parts must be shielded to prevent skin contact; 

 

the Lubricus Lubrication System must be used according to the Technical Data and instructions; 

 

the limit values stated in the Technical Data are under no circumstances to be exceeded;  

 

retrofitting and repair work on the Lubricus Lubrication System may only be carried out by the manufacturer;  

 

the lubrication system must be protected against damp and wet. 

 

If a lubricant that has not yet been tested for compatibility with the Lubricus Lubrication System be supplied or requested for 
use  in  the  Lubricus  Lubrication  System  by  the  purchaser/customer,  the  purchaser/customer  undertakes  the  risk  and 
responsibility.  

 
This product is subject to strict production controls and fulfils our company’s factory specifications. However, guarantee of 
testing of each individual case cannot be given due to the numerous factors involved.  

We therefore strongly recommend that test runs be carried out.

  

All liability is excluded.  

 
The Lubricus Lubrication System lubricant cartridge has been constructed and produced for 

one-time use

 only. Multiple use 

of the lubricant cartridge is not envisaged. After being used once, the lubricant cartridge is to be completely replaced; refilling 

is not permitted. Noncompliance will lead to nullification of the guarantee. 
 

For guarantee conditions see the sales and delivery conditions of Grützner GmbH 

 

Attention

Summary of Contents for Lubricus LUB-C-1

Page 1: ...User Guide Lubricus Controller LUB C 1 LUB C 2 LUB C 3 LUB C 4 LUB C 1 1 24 VDC Lubricus Type C...

Page 2: ...11 12 Activation of exits Pump specific adjustment 10 12 Inputting the generation of the Lubricus C devices used 13 Table pause time adjustments 14 Table quantity adjustment 14 Details Activation Sta...

Page 3: ...e installed in a central location Depending on the configuration of Lubricus Lubrication System Type C is available with up to four outlets and therefore suitable to lubricate several lubrication poin...

Page 4: ...the clear housing to remove the key for Setup or Adjustments of your Lubricus Simply turn clockwise to release key The point of the key is used for programming Please note Always replace the key for...

Page 5: ...ccessories and by observation of all installation operation and maintenance instructions Gr tzner GmbH excludes all liability if these instructions are not observed Gr tzner GmbH grants guarantees con...

Page 6: ...directly on the machine must be strictly followed and maintained in completely readable condition Qualification and training of the personnel The operation maintenance service and installation personn...

Page 7: ...th the manufacturer Original spare parts and accessories authorized by the manufacturer are for safety purposes Using other parts results in loss of liability for claims resulting out of this For comp...

Page 8: ...al connection Have the electric power supply connected only by a trained electrician Connection and wiring of the electric components should be done by an expert trained in this field Check the voltag...

Page 9: ...stallation Lubricus Controller settings Observe the safety instructions The programming mode enables Lubricus will be installed near the lubrication point Entering the quantity of exits per Lubricus I...

Page 10: ...page 10 Adjustment Flow chart...

Page 11: ...exit activated A01 1 exit activated A02 2 exits activated Settings for every specific Lubricus Models Type LUB C 1 adjustment at green LED left Lubricus body 1 exit A01 adjustment at orange LED right...

Page 12: ...Lubricus body 2 outlets is dispensing equal quantity Typ LUB C 4 adjustment at green LED left Lubricus body 2 exits A02 adjustment at orange LED right Lubricus body 2 exits A02 Left and right side of...

Page 13: ...parameter on the controller as all Lubricus controllers with n01 r03 software are set to the PU2 generation on delivery In accordance with this Pu2 is shown on the display After approx 4 seconds the d...

Page 14: ...bricus 1 side of body H Pause Time adjustment Time between 2 lubrication intervals 1 to 96 h possible H Pause Time hours 1 12 24 48 96 Result Lubrication cycles per exit per month 720 60 30 15 7 5 Int...

Page 15: ...orange LED Lubricus unit 2 green LED than orange LED Lubricus unit 3 green LED than orange LED Lubricus unit 4 green LED than orange LED Basic settings all Controller exits are not activated 3 After d...

Page 16: ...tment at green LED left side of Lubricus body 2 Exits A02 Touch sensor shortly with programming key until required information is displayed If there is no change the displayed value will be used After...

Page 17: ...es from 15 This is accurate enough to establish the condition of the lubrication point 5 Additional functions QuickCheck extra dispensing cycle pumping of small amounts of lubricant for testing purpos...

Page 18: ...when the sequence of the connected pump with the error is reached If the sequence reaches the units without error the display will show ON the red LED will still light to signal that an error message...

Page 19: ...nnected units will dispense as per program in memory Corrective action Change or connect cable broken missing or disconnected connection cable Switch unit OFF and On again The error message will be re...

Page 20: ...Imax approx 350 mA during pump operation typically 200 mA Standby current standby mode 20 mA Input Signal can switches ON and OFF PIN 2 no assignment PIN 3 Ground GND PIN 4 High operating mode OK inpu...

Page 21: ...serve the safety instructions Switch off Lubricus Controller 2 Take out ventilation locking turn clock wise to OPEN 3 Press the housing turn left and remove it 4 Remove the empty cartridge 5 Remove pr...

Page 22: ...rror report will be deleted Technical Data Lubricus Controller Control micro processor controlled up to 4 Lubricus units Type C can be connected Power supply 24 VDC Power consumption max 300mA typical...

Page 23: ...m outside and 4mm inside diameter Operating pressure max 70 bar Operating temperature 20 C to 80 C Dimensions max Width x height x depth 112 x 196 x 94 mm Weight without lubricant 1120g Control Lubric...

Page 24: ...age 24 Mounting Lubricus unit 2 srews 6mm for example M6x40 are required for a safe installation of your Lubricus The optimum clamping force of the screw is 5 Nm 3 points at the back assure a safe hol...

Page 25: ...re vs to tube length tested with tubes 6 x 4 mm Disposal When disposing lubricant the waste disposal instructions of the lubricant manufacturer must be observed Disposal of Lubricus Lubrication System...