Start up (Switch on / Switch off / Change)
Lubricus Controller can be adjusted without any Lubricus unit attached. Settings will stay in memory. Lubricus Controller
controls the connected Lubricus in sequence one after the other. This ensures no Lubricus unit is operating parallel
preventing higher energy usage. During pump operation no further changes and functions are possible.
(1)
Connect Lubricus Controller with M12x1 Plug to 24 VDC (e.g. via PLC), power consumption max. 300 mA (more
details in communication interface, page 18) after connection 24 VDC -> green LED illuminated (constant light)
(2)
Lubricus Controller displays ON, the display will show all values in the display associated with the assigned LED
light. Lubricus unit 1: green LED, than orange LED; Lubricus unit 2: green LED, than orange LED; Lubricus unit 3
green LED, than orange LED ; Lubricus unit 4: green LED, than orange LED.
Basic settings:
all Controller- exits are not activated.
(3)
After displaying all adjustments, ON is blinking for approx. 3 sec in the display :
Now
you can adjust the basic
settings.
Open the ventilation lock (turn clockwise to OPEN) and remove the cover. The nose of the cover is your Operating /
programming key.
green LED: Function left side of Lubricus body
orange LED: Function right side of Lubricus body
All adjustments and changes will be executed by touching
the sensor area on the Controller with the activation and
programming key.
Normal Status Indication:
F: red LED – constant light – failure, fault, error report
OK: green LED – constant light – everything OK
If no further action the
Controller will continue in the
operating mode. Place
activation and programming
key in
ventilation hole and
turn it from OPEN -> CLOSE