E4
:
Lubricus-feedback
: Exit was activated, but no feedback from connected Lubricus unit: red LED lights cons
Display will show error for unit connected to Lubricus Controller exit +
E4
; the red LED will light additionally to the green and
orange LED when the sequence of the connected unit with the error is reached. If the sequence reaches the Lubricus units
without error the display will show “ON”, the red LED will still light to signal that an error message exists.
Root cause:
The connection cable between Controller and Lubricus unit is broken, disconnected or missing. Lubricus
Controller unit stays active and other connected units will dispense as per program in memory.
Corrective action: Change or connect cable (broken, missing or disconnected connection cable), Switch unit „OFF“ and
„On“ again. The error message will be reset to 0. Lubricus will start again as per program in memory
Example:
Exit 1, Lubricus LUB-C-2, all OK
Exit 2, Lubricus LUB-C-1-1, cable defect
System error:
Switch unit „OFF“ and „On“ again, Memory will not be erased.
Extras:
”Quick check” back pressure measurement
For testing purposes the Lubricus Controller is equipped with the “Quick Check” back pressure measuring function.
Quick
Check back pressure measurement uses the extra lubrication cycle.
A simple touching of the programming key to the
sensor pad will measure the existing pressure between the lubrication point and the pump unit exit. The value in bar will be
shown in the display.