page 14
2)
If exits are activated (A01 or A02), each side of Lubricus body half can be adjusted:
H = Pause Time =>
Time interval between 2 lubrication intervals (1 to 96 h possible)
than
C = Lubrication quantity per interval =>
(
1
x 0,15 cm
³
to
30
x 0,15 cm
³
= 4,5 cm
³
possible)
H = Pause Time
H: Adjustment for
Lubricus – 1 side of body
H (Pause Time) adjustment = Time between 2 lubrication intervals
(1 to 96 h possible)
H: Pause Time (hours)
1
12
24
48
96
Result: Lubrication cycles per exit per
month
720
60
30
15
7,5
Intermediate steps are possible.
C = Lubrication quantity per interval
C:
Adjustment for
Lubricus – 1 side of body
C (number of strokes) adjustment
= delivery rate of one period
Number of strokes
1
5
10
20
30
Delivery rate
of one period
0,15cm³
0,75cm³
1,5cm³
3,0cm³
4,5cm³
Intermediate steps are possible.