page 21
Service: replacement of cartridge: Lubricus , Type C, modell with cartridge
(error report: E1, empty cartridge)
1. Observe the safety instructions. Switch off Lubricus Controller
2. Take out ventilation locking (turn clock wise to OPEN)
3. Press the housing, turn left and remove
it
4. Remove the empty cartridge.
5. Remove protection from the new cartridge
6. Lubricate O-Ring of the new cartridge slightly.
7. Place the cartridge on the inlet
Summary of Contents for Lubricus LUB-C-1