Output Monitoring
Figure 113. RCE Size Setting for Destination Monitors
This illustration assumes we want to configure 128 Destinations, 128
Sources, and eight Destination monitors. In this case the number of Desti-
nations is increased by eight from 128 to 136 to incorporate the eight Desti-
nation monitors. The number of Sources is also increased by eight to
maintain a symmetrical configuration.
2.
While configuring the Physical Matrices enter the maximum number of
monitors intended to be configured for this matrix type. See