126
Encore — Configuration Manual
Section 5 — Router Configuration
Configuring a Physical Matrix
The following procedures continue from
, but can be used to configure a Physical Matrix at any
time.
Note
S
for examples of several con-
figurations of Physical and Logical Matrices,
S
egments, and Elements.
13.
Click the
Phys Matrix
button on the System Configure Main menu.
14.
Use the
Select
button in the CrossPoint Group section of the screen to
choose an undefined Crosspoint Group (~Undef Xpt Group
n
).
15.
Click in the
Name
field and type a more meaningful name, for example,
Washington SD.
16.
Click in the
No. Inputs
field and type the number of inputs.
This entry is copied into the
Last Input
field in the Segment section of the
screen because the default configuration is one Segment in the Cros-
spoint Group that is the same size as the whole Crosspoint Group.
17.
Click the
No. Outputs
field and type the number of outputs.
This entry is copied into the
Last Output
field in the Segment section of
the screen because the default configuration is one Segment in the Cros-
spoint Group that is the same size as the whole Crosspoint Group.
18.
In the
No. Controllers
field, indicate the number of controllers used in this
Crosspoint Group.
The controller limit is 32. An entry for each controller will appear in the
Controller Select list window when you click the
Select
button in the
Controller section of the screen.
19.
In the
No. Segments
field, indicate the number of Segments for this
configuration.
The limit is eight. If you indicate more than one Segment, follow these
procedures through
, then proceed to
20.
If you’re using Grass Valley Group’s CPL, click the
Matrix Type
button
and choose the desired matrix type from the list window which
appears. Otherwise you can skip this step.
Select Connector
Allows selection of a connector number by scrolling
through a list or specifying a connector number.
Up Down Arrows
Pages up or down one page per click.
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...