GM · CONVERTING UNIT
58
21.
Operator Maintenance Chart
Unit
Module
Every Activity
Tools
Remarks
Converter
All nips
and rollers
1 day
Clean for
varnish and glue
Cloth, alcohol
Converter
Anilox/ductor
doctor blade ink
tray
7 days Clean for
varnish/ink
Cloth, uv wash
Replace doctor blade
if it’s damaged
Converter
Flexo unit
1 day
Inspect side scraper and doctor
blades.
The doctor blade holder must
NEVER touch the anilox
(heavy damage)
Allan key.
Side scrapers must be tight
against the doctor blade (90
deg angel) and anilox
Converter
Flexo unit
1
week
Clean down unit completely and
greas brass side movement
adjuster
UV cleaner +
standard
machine greas
Converter
Flexo unit
1
month
Check diameter on print roller.
New roller has Ø97.2. At Ø96.5
the unit stops working
Calibre
Always keep a spare print
roller
Chiller
Water level
1
month
Refill if necessary
Tap water
Chiller
Return filter
1
month
Clean if necessary
Converter
All belts
1 year Tighten if necessary
check that belts are ok
Replace belt if it’s
damaged
Converter
UV lamp (Bulb,
hoses)
1000 h Replace bulb
check that hoses are ok
Replace hoses if it’s
damaged