GM · CONVERTING UNIT
16
6.
Menu buttons
Just below the machine drawing, you will find two white boxes. In the left box, two counters are placed:
A meter counter and a label counter. Each can be cleared by pressing the clear button [
0]. Additionally,
the label counter can be turned on and off with the checkbox next to the counter. In the right box, info
messages, warnings and alarms will show up when the machine has something to report.
The 'Automatic stop at low unwinder diameter' feature makes the converting unit stop when the roll on
the unwinder spindle becomes smaller than a value entered in the Parameter menu.
When in inline mode this function is bypassed.
The 'Automatic stop at label preset' feature makes the converting unit stop when the label counter reaches
or exceeds the preset value entered in the Parameter menu.
'UV min. power' is the minimum power that the UV lamp will deliver when the web is moving. When
web speed increases, the output power will also be increased. The value is altered by pressing the two
arrow-buttons to the left.
'UV power gradient' is the rate at which the power increases when web speed increases. The actual unit is
[W/(m/min)], i.e. with a web speed of 20 m/min, and a gradient of 200, the output power will be 4000 W.
The absolute maximum output power is 5000 W.