14
309085
Installation
Connecting the Electrical Control Panel to
a Power Source
The electrical control panel (Fig. 5) comes already
attached and wired to the ram, however before the
supply unit becomes functional, you must connect the
electrical control panel to a power source.
WARNING
ELECTRIC SHOCK HAZARD
Do not connect the electrical control
panel to a power source unless you are
a trained professional. Failure to follow
standard procedures or to observe the necessary
precautions could result in serious bodily injury or
equipment damage.
Fig. 5
TI0535
Have a trained electrician connect the electrical control
panel (Fig. 5) to a grounded electrical source that has
the required service ratings:
CAUTION
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty will be voided. Check the label on the con-
trol box for the proper voltage.
AC
Panel
Voltage
Hz
Phase
*
Platen
Selection
Full
Load
Amps
220/240
50/60
3
B–1 & B–3
70
B–2
80
380/400
50/60
3
B–1 & B–3
42
B–2
48
470/490
50/60
3
B–1 & B–3
35
B–2
40
570/590
50/60
3
B–1 & B–3
29
B–2
32
B–1 = Standard grid platen: 18 Kw
B–2 = Mega–Flow platen: 21 Kw
B–3 = Smooth bottom platen: 18 Kw
For information about specific terminal locations and
connections, see
Control Panel Component Layout
on page 74 and refer to Electrical Setup in Graco form
309180, Therm–O–Flow Plus Installation and Opera-
tion Guide
To connect the control panel to the electrical source:
1. Locate the opening in the control panel‘s top
housing for the conduit that will enclose the wire
from the facility’s power source. The hole will
accept a 1” conduit fitting. It is 1.3” dia. (33mm).
2. Thread the wire from the power source into the
control panel housing, and then connect the power
source wires to the appropriate terminals on the
DISCONNECT switch.
Summary of Contents for Therm-O-Flow Plus
Page 22: ...22 309085 Notes...
Page 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Page 30: ...30 309085 Notes...
Page 43: ...43 309085 Notes...
Page 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Page 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Page 65: ...65 309085 Notes...