10
309085
Typical Installation
Heat Control Zone Selection
The Therm–O–Flow Plus can be ordered withsix (code
E–1) or eight (code E–2) heat zones (see Fig. 3).
Zones 1 and 2 are always used for heated drum platen
and the heated pump. Zones 3 and 4, 5 and 6, and
optional zones 7 and 8 are each available as paired
zones through a 16–pin connector. The heated hoses
have a 16–pin connector on the inlet end cable, and an
8–pin connector on the outlet end cable. All heated
valves, manifolds and heaters are equipped with an
8–pin matching connector. Accessory cables are
available for other possible combinations.
TI0536
Fig. 3
NOTE: Zone seven can be used for hoses up to 15 ft. (4.5 meters) or a heated
header or any accessory device up to 750 watts with the right accessory
cable. Zone eight can be used for hand guns or automatic valves only.
ZONE
1
Control
ZONE
2
Control
ZONE
3
Control
ZONE
4
Control
ZONE
5
Control
ZONE
6
Control
ZONE
7
Control
ZONE
8
Control
Valve 1
Valve 2
Valve 3
Hose 1
Hose 2
Hose 3
Platen
Pump
1250 watts
max
500 watts
max
1250 watts
max
750 watts
max
250 watts
max
500 watts
max
Summary of Contents for Therm-O-Flow Plus
Page 22: ...22 309085 Notes...
Page 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Page 30: ...30 309085 Notes...
Page 43: ...43 309085 Notes...
Page 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Page 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Page 65: ...65 309085 Notes...