Installation
Overview of the Temperature Controller Settings
The basic program settings for each temperature con-
troller satisfy most application needs. These settings
are preset at the factory, but can be changed. The
input type, temperature scale, and over temperature
alarm point are the critical controller settings that are
set before doing an auto-tune or using any controller in
normal operation. See Form 309100 for operation of
the temperature controls.
Graco Factory P, I, and d Settings
Table 2 lists the P, I, and d settings for standard control
panels. These settings are preset at the factory. Use
the table for reference information only.
Table 2. Graco Factory P, I, and d Settings
Category
P
I
d
Unit Voltage
Ram Plate
41
118
29
ALL
Pump
50
1186
296
ALL
Hose
9.9
51
12
ALL
Gun
75
49
12
ALL
Manifold
24.1
144
36
ALL
Compensator
40.9
87
21
ALL
Header
1.7
109
16
ALL
Regulator
58.5
330
82
ALL
These P, I, and d values are usually generated by
running an autotune process for each heat zone. The
controllers will automatically find the proper P (propor-
tional), I (integral), and d (derivative) values during this
autotune process. These are values that allow the heat
zones to reach their maximum temperature as fast as
possible without significantly exceeding desired tem-
perature.
It is not recommended that “AutoTune” be used for the
heated pump zone.
Summary of Contents for Therm-O-Flow Plus
Page 22: ...22 309085 Notes...
Page 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Page 30: ...30 309085 Notes...
Page 43: ...43 309085 Notes...
Page 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Page 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Page 65: ...65 309085 Notes...