42
309085
Advanced Pendant Control
Load Graco Defaults
This selection is not normally used when receiving a
new system from Graco. This is used to setup all the
parameters within each zone controller, the alarms
values, the units of measure (
F or
C) and various
setup parameters not accessible by the user. It will be
useful if a temperature controller has been replaced or
access has been gained to a temperature controller
and settings have been changed which affect the
operation of the system. The LOAD DEFAULTS
selections automatically loads all the setup parameters
that are important to the operation of the system to
each ACTIVE temperature controller. It loads the
current configured PID TYPES along with the proper
alarms settings for each control. The user is prompted
for the unit when when this is selected.
To LOAD DEFAULTS, access the SETUP screens by
entering the correct PASSWORD, acknowledge the
proper amount of zones are configured, and proceed
to the following screen.
8 = D A T E / T I M E
C H A N G E
9 = L O A D
D E F A U L T S
0 =
B A C K
F1
F2
F3
F4
F5
Press 9 on the numeric keypad.
S E L E C T
U N I T
F
Q U I T
C
F 1
F 3
F 5
F1
F2
F3
F4
F5
If this screen is accessed by accident, press F3
(QUIT) to return to the previous screen. Pressing F1
(F) will send all the settings to all the ACTIVE zones
with the proper settings for
F operation. Pressing F5
(C) will send all the setting to all the ACTIVE zones
with the proper settings for
C operation.
The display will change, showing the sending of PID
values and other setup parameters to different zones.
Watching the temperature controllers, you will see
some screen changes and the pendant will beep as it
finishes each setup. The zones are placed in the
STOP mode when complete.
Once done, all the zones are configured for proper
operation with the Therm-O-Flow Plus system. Use
this selection if some of the critical setup parameters
on the temperature controller setup screens have been
changed, or a temperature controller has been
changed.
NOTE: The temperature controls have also been set
for
F or
C. This can be verified on the display of
each temperature control while being powered up.
Refer to manual 309100. Using the pendant with this
procedure is a much easier means of converting from
one unit to another. The pendant will remember the
last unit sent to the controls and will continue to prompt
for the proper temperature unit when editing and
sending SV temperature settings.
Summary of Contents for Therm-O-Flow Plus
Page 22: ...22 309085 Notes...
Page 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Page 30: ...30 309085 Notes...
Page 43: ...43 309085 Notes...
Page 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Page 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Page 65: ...65 309085 Notes...