12
309085
Installation
The installation procedure includes:
locating and installing the ram
electrically connecting hoses to the electrical con-
trol panel
grounding the system
connecting the electrical control panel to a power
source
checking resistance
setting controls on the electrical control panel
Graco form 309180, Therm–O–Flow Plus Installation
and Operation Guide, includes:
starting up the system
initially loading material
Installing the Ram
To install the ram, follow the procedure below. Refer to
the Ram Mounting and Clearance Dimensions drawing
on page 79 for ram mounting and clearance dimen-
sions.
1. Select a convenient location for the equipment.
Check that there is sufficient overhead clearance
for the pump and ram when the ram is in the fully
raised position. Make sure the air regulators for the
pump and ram are fully accessible.
2. Level the base of the ram, using metal shims.
3. Using the holes in the base as a guide, drill holes
for 13 mm. (1/2”) anchors. Bolt the ram to the floor
with anchors, which are long enough to prevent
the unit from tipping. Refer to the Dimensional
Drawing on page 79.
Electrically Connect Hoses to the
Electrical Control Panel
WARNING
FIRE HAZARD
Only use hoses that have a maximum
wattage less than or equal to 1250
watts. Using hoses with higher maxi-
mum wattage could create a runaway
temperature condition.
Assemble the hose and gun components as needed.
For information on connecting the hose and gun com-
ponents, follow the gun’s instructions.
Electrically connect the hoses to the electrical control
panel. The connectors are located on the back of the
electrical control panel (Fig. 4).
1. Connect the plug from hose 1 to the Hose 1/Gun 1
receptacle.
2. Connect the plug from hose 2 to the Hose 2/Gun 2
receptacle.
Fig. 4
Rear View of Electrical Control Box
TI0538
Hose One
Hose Two
Hose Three (optional)
Summary of Contents for Therm-O-Flow Plus
Page 22: ...22 309085 Notes...
Page 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Page 30: ...30 309085 Notes...
Page 43: ...43 309085 Notes...
Page 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Page 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Page 65: ...65 309085 Notes...