3A5856A
Advanjet HV-2000C Jet Controller Setup and Operation
Page 37 of 60
7.5
Heater Commands
SH
Set Heater Temperature
# nTemperature;
The
SH
command allows the host to set the temperature for the Heater Controller in the
Advanjet Controller.
# nTemperature
Sets temperature value in
degrees Celsius
.
This value should be
less than 75
degrees Celsius (167 °F).
SO
Turn Heater On/Off
# nFlag;
The
SO
command allows the host to turn On or Off the heater in the controller.
# nFlag
Sets #nFlag; 1 = turn heater on and 0 = turn heater off
HF
Heater Off timer
# nMins;
The
HF
command gives the host the ability to automatically turn the heater off after a
specified Jet idle time.
# nMins
Sets the idle Jet time in
minutes
Example: The following commands will set the heater temperature to 50 degree Celsius
(122 °F), the idle time to 5 minutes and turn on the heater.
SH 50;
HF 5;