Advanjet HV-2000C Jet Controller Setup and Operation
3A5856A
2.4
Input / Output Connections
A standard, 5-foot 26-pin Input/Output cable is supplied with the HV-2000C. The table
below describes the I/O connector pin assignments. The I/O is configured for the inputs
to be pulled down to GND. When the specific input is triggered, the Advanjet controller
will activate the corresponding preprogrammed Recipe # shown.
Pins 1 through 6 are outputs from the robot to the Advanjet controller.
They can be TTL outputs capable of sinking 2 mA of current,
or they can also be relay contacts.
Pin 7 outputs a busy status flag from the Advanjet controller to the robot.
Pin 8 is an external interrupt used to remotely stop a dispensing program.
Pins 9 and 14 are Isolated Ground.
Pins 18-26 are alarms from the heater and pressure sensors.
I/O PIN ASSIGNMENTS
HD26 HV-2000C
1
Recipe 1 (Input)
2
Recipe 2 (Input)
3
Recipe 3 (Input)
4
Recipe 4 (Input)
5
Recipe 5 (Input)
6
Recipe 6 (Input)
7
Busy Flag (Output)
8
External Interrupt (Input)
9
GND
10
D/A Converter Output
11
Buffered A/D Converter Inputs
12
Buffered A/D Converter Inputs
13
D/A Converter Output
14
GND
15
No connection
16
No connection
17
No connection
18
Heater Alarm Common (Output)
19
Fluid Pressure Alarm Common 2
20
Fluid Pressure Alarm 2 (Output)
21
Fluid Pressure Alarm 1 (Output)
22
Jet Pressure Alarm Common 1
23
Jet Pressure Alarm 2 (Output)
24
Jet Pressure Alarm 1 (Output)
25
Heater Alarm 1 (Output)
26
Heater Alarm 2 (Output)
Note:
Refer to Appendix 4 for I/O connection details.