![Graco Advanjet Diaphragm-Jet HV-2000 Setup And Operation Download Page 27](http://html1.mh-extra.com/html/graco/advanjet-diaphragm-jet-hv-2000/advanjet-diaphragm-jet-hv-2000_setup-and-operation_2251220027.webp)
3A5856A
Advanjet HV-2000C Jet Controller Setup and Operation
Page 27 of 60
6.2
Programming Timing Recipes
The Advanjet software offers several sample Timing Recipes for popular fluids for a
quick start-up. As shown in Figure 6-1 above, the Timing Recipes main menu screen
lists the dispensing parameters on the HV-2000C controller front panel.
Timing Recipe List:
Up to twelve
Timing Recipes can be programmed.
Each Timing Recipe should have a
distinct and unique name. Since these
names will be used to identify fluid
values and are used in the recipe list in
the Settings screen, a good choice for a
name is the specific fluid or material
type (SMA-100Hz, UV-100 cps) or part
number, as shown in Figure 6-2 at left.
TIMING
RECIPES LIST
(1
– 12)
DWELL TIME
REFILL TIME
TIME
(FOR FIRST
DROP)
Figure 6-1: Timing Recipes Main Menu
Figure 6-2: Timing Recipes List