![Graco Advanjet Diaphragm-Jet HV-2000 Setup And Operation Download Page 7](http://html1.mh-extra.com/html/graco/advanjet-diaphragm-jet-hv-2000/advanjet-diaphragm-jet-hv-2000_setup-and-operation_2251220007.webp)
3A5856A
Advanjet HV-2000C Jet Controller Setup and Operation
Page 7 of 60
1.2
HV-2000C Controller Specifications
PARAMETER
SPECIFICATION
Size
Width: 254.0 mm (10.00 in)
Height: 152.5 mm (6.00 in)
Depth: 341.4 mm (13.44 in)
Weight: 3200 g (7.05 lbs)
Drop Parameters
Refill time and Dwell (0.1 msec resolution)
Number of drops (programmable from 1 to 1M)
Recipes
6 independent recipes, manual or remote triggers
Nozzle Heater
Heating to 70
C Max
± 1.0
C @ 50
C
PID control using platinum RTD, Auto tuning
24 VDC, 5.7 W, 100
Ω
Programmable shutoff timer
2 alarms for process control
First Drop Compensation
2 levels with programmable time interval
Interface
RS-232 Serial Port
LCD Display with Keypad
Input/Output
TTL level triggers
Operating Temperature
15
°
C to 50 °C (59 °F to 122 °F)
Input Pressure
0.6 MPa (90 psi) - maximum
Input Power
100
– 240 VAC, 50/60 Hz, 115 W
Fuse: 5x20 mm, Fast-acting, 1.6 amp, 250 VAC
Advanjet Software
Windows XP, Vista, Windows 7 and Windows 8
Approvals
1.3
Technical Assistance
For technical assistance:
Phone:
+1 760-294-3392
Web:
E-mail: