GMC-I Messtechnik GmbH
69
OUTPUT, OUTPUT? – Activate / Deactivate the Output
Function and manual operation:
See explanation in chapter 3 [3].
Settings
Programming
Setting command:
OU
TPUT
txt
Parameter:
txt (
status)
Parameter type:
Text (character)
Setting command
OFF
Deactivate the output
ON
Activate the output
Example
(HP Basic):
OUTPUT 713;"OUTPUT ON"
{activate output}
Query
Displays the selected status of the power output.
Programming
Query command:
OU
TPUT
?
Response string:
OUTPUT
txt
Length: 10
characters,
fixed
Parameter:
txt (status)
Example
(HP Basic):
OUTPUT 713; "OUTPUT?"
ENTER 713; A$
DISP A$
Display:
OUTPUT ON
OVSET, OVSET? – Overvoltage Protection Trigger Value
Function and manual operation:
See explanation on page 25 -
OVP.
Settings
Programming
Setting command:
OVS
ET
v
Parameter:
v (
value)
Parameter type:
Real number
Setting range
0
v
OVSET
max
Format: +nnn.n
Example
(HP Basic):
OUTPUT 713;"OVSET 35.0"
{trigger value 35 V}
Query
Programming
Query command:
OVS
ET
?
Response string:
OVSET
v
Length: 12
characters,
fixed
Parameter:
v (value)
Format: +nnn.n
Example
(HP Basic):
OUTPUT 713; "OVSET?"
ENTER 713; A$
DISP A$
Display:
OVSET +035.0
POUT? – Querying the Momentary Power Value
Function and manual operation:
Momentary values for
output voltage
and
output current
are
acquired by means of the
POUT
function.
The two
measured quantities
are
multiplied
to arrive at power
value
Pout
.
Approximately 90 ms are required to acquire and process the
measured values.
See explanations in chapter 4.8.1.
Programming
Query command:
POU
T
?
Response string:
POUT
v
Length: 12
characters,
fixed
Parameter:
v (value)
Format: +nnnn.n
Example
(HP Basic):
OUTPUT 713; "POUT?"
ENTER 713; A$
DISP A$
Display:
POUT +0074.2
POWER_ON, POWER_ON? – Output Switching Status, Response After Power On
Function and manual operation:
See explanation on page 26.
Programming
Setting command:
POW
ER_ON
txt
Parameter:
txt (
status)
Parameter type:
Text (character)
Setting range
RST
RESET: device default settings
RCL
RECALL: last used device settings
SBY
STANDBY: last used device
settings, but power output remains
inactive (OUTPUT OFF).
Example
(HP Basic):
OUTPUT 713;"POWER_ON RST"
{KONSTANTER is set to default settings
after power-up}
Query
Displays device setting which determines status after power-up.
Programming
Query command:
POW
ER_ON
?
Response string:
POWER_ON
txt
Length: 12
characters,
fixed
Parameter:
txt (status)
Example
(HP Basic):
OUTPUT 713; "POWER_ON?"
ENTER 713; A$
DISP A$
Display:
POWER_ON RST
Device Type
Nom. voltage [V]
20
40
80
360
OVSET
max
[V]
25
50
100
450
Step size [mV]
100
200
400
2000