46
GMC-I Messtechnik GmbH
4.10.2 Recall from SEQUENCE Memory
Addresses 11 to 255: Uset, Iset, tSEt and SSEt values for the
sequence function
!
Data from memory locations 11 through 255 can be recalled
at any time during programming.
☞
Press the <
RCL
> key.
!
rcl
appears at the left-hand display, and the last selected
memory location number appears at the right-hand display.
☞
Select the desired address (11 ... 255) by pressing the <
>
key or the <
> key.
☞
Acknowledge your selection with the <
ENTER
> key.
!
Iset and Uset settings saved to this address blink at the display.
☞
Browse through this memory location with the <
SELECT
> key
in order to view the respective parameter settings (see chapter
4.8).
☞
All of the data saved to this memory location can now be
loaded by once again pressing the <
ENTER
> key.
!
If one of the recalled Uset or Iset values exceeds the currently
valid soft limit (Ulim and Ilim), execution of the command is
aborted,
Err 21
is displayed briefly and bit 5 is set in event
register B.
!
Only Uset, Iset and SSEt are executed: tset is loaded as a
current setting value but is not executed.
☞
Another memory location can be immediately accessed with
the <
> key or the <
> key while the previous function is
being executed.
☞
Press the <
CE/LOCAL
> key to abort the
RECALL
function.
☞
Press the <
RCL
> key in order to return to the memory location
selection function.
☞
The
RECALL
function can be exited and another function
accessed by pressing any other function key, or by turning the
adjusting knob.
4.11 Disabling Front Panel Controls
The front panel controls can be disabled against inadvertent
changes to selected values and settings.
The behaviour during mains ON is also influenced by the selected
power-on status Pon parameter (page 26).
Disabling
☞
Simultaneously press the <
CE/LOCAL
> and <
SAVE
> keys.
!
The front panel controls are now disabled.
!
The yellow
LOCKED/SEQ
LED lights up.
Enabling
☞
Press and hold the <
CE/LOCAL
> key for at least 4 seconds, or
until the
LOCKED/SEQ
LED goes out.
Note:
While key is pressed and sequence is in progress, „LLO“ is
shown in the display.
Disabling and Enabling via the Analog Interface
☞
The
<CE/LOCAL>
key can also be disabled by applying a signal
to the trigger input at the analog interface and selecting the
appropriate setting for the
T_MODE
function, thus preventing
manual reactivation of the front panel controls.
4.12 <The ENTER> Key
The <ENTER> key is used to execute various functions in
combination with the respectively selected operating mode.
<ENTER> Key Functions
Pre-Selecting Setpoints (fixed value selection)
1) <
ENTER
>: Change display from Uout/Iout to Uset*/Iset.
2) <
> or <
>: Preselect Uset, Uset LED blinks.
3) <
ENTER
>: Activate Uset value.
4) <
ENTER
>: Change to Iset*.
5) <
> or <
>: Preselect Iset, Iset LED blinks.
6) <
ENTER
>: Activate Iset value.
* The decimal place which can be adjusted with the <
SELECT
>
function blinks.
See also page 21, “Pre-Selected Settings”.
Activating Parameter Values
Textual or numeric parameter values are activated with the
<
ENTER
> key during device setup.
Executing Commands
<
SAVE
>: Save data to the selected address.
<
RCL
>: Recall data saved to the selected address. After pressing
the <
ENTER
> key the first time, the selected data blink at the display, and
are then executed after pressing the <
ENTER
> key once again.
Sequence control: Execution of SEq xxxx commands
Function group selection: Access parameter settings for the
selected function group
Sequence and Step-by-Step Control
A running sequence can be suspended by pressing the <
ENTER
> key.
Status change: RUN
HOLD
A suspended sequence can be resumed by pressing the <
ENTER
> key.
Status change: HOLD
RUN
The next memory location can be executed by pressing the
<
ENTER
> key in the step-by-step control mode.
4.13 The <CE/LOCAL> Key
The
<CE/LOCAL>
key is used to execute a specific function in
combination with the respectively selected operating mode.
Reset Device Settings
☞
<CE/LOCAL> key + <ENTER>
: The KONSTANTER’s factory
default settings are used.
Disable and Enable Front Panel Controls
Switch from REMOTE to LOCAL
Abort an Operation
Uset / Iset Entry
☞
<CE/LOCAL> key
Switch to display of measured Uout and Iout values.
<SELECT> Display
☞
<CE/LOCAL> key
Switch to display of measured Uout and Iout values.
<SAVE> / <RCL> Function
☞
<CE/LOCAL> key
Abort <SAVE> and <RCL> functions, switch to display of
measured Uout and Iout values.
Function Group Selection
☞
<CE/LOCAL>
Return to display of measured Uout and Iout values from
function group selection.