8
GMC-I Messtechnik GmbH
1.5 Technical Data
1.5.1
General Data
Power Supply
Connection
Input:
10 A IEC inlet plug
Output:
10 A IEC inlet socket,
without switch,
without fuse
Line voltage
230 V ~ +10 -15%, 47 to 63 Hz
Power consumption
See chapter 1.4.3
Inrush Current
Max. 50 A
S
Mains fuse
1 ea. T 4 A / 250 V (6.3 x 32 mm, UL)
internal: 1 ea. T 5 A 250 V (5 x 20 mm)
Output
Connection
Output
Front panel, 2 ea. 4 mm safety jacks
Rear , 6-pole plug-in screw terminal block
Sensor
Rear panel, included in 6-pole plug-in
screw terminal block
Analog interface
Rear, 11-pole plug-in screw terminals
Regulator type
Primary switched-mode regulator with
BET technology
Operating modes
Adjustable constant voltage / constant
current source with automatic sharp
transition
Output isolation
Floating output with “safe electrical
separation” from the mains input and
computer interfaces
Max. allowable potential, output–ground:
120 V, capacitance, output–ground
(housing) 60 nF
Output operating range
Short-term range:
If lengthy operation in the short-term
range occurs, overtemperature protec-
tion may be triggered resulting in output
shutdown (see also short-term power in
chapter 1.5.3).
Figure 1.5
Dimensional Drawing (benchtop device)
Analog Interface
Connection
11-pole plug-in screw terminal block
Reference potential Output minus pole, floating TRG input
Connector pin assignments:
Addressable V.24 – RS 232C Interface
Input
9-pin subminiature socket connector
Output
9-pin subminiature plug connector
Operating mode
half-duplex, asynchronous, XON / XOFF
Transmission speed adjustable from 50 to 19,200 bits per second
Device address
selectable from 0 to 30 or UNL (unlist)
Max. Setting Rate
approx. 15 settings per second
Max. Sampling Rate approx. 7 measurements per second
IEC 625 – IEEE 488 Interface (optional)
Connection
24-pin socket connector
per IEC 625.1, IEEE488.1
Interface
SH1 SOURCE HANDSHAKE
functions
handshake source function
AH1 ACCEPTOR HANDSHAKE
handshake sink function
T6
TALKER
talker function with serial polling
and automatic unlisting,
no secondary address and no
talk-only operation
L4
LISTENER
listener function with automatic
unlisting, no secondary
address and no listen-only operation
SR1 SERVICE REQUEST
service request function
RL1 REMOTE / LOCAL
remote to local switching
function with disabling
DC1 DEVICE CLEAR
reset function including selected
device clear
PP1 PARALLEL POLL
parallel polling function with remote
configuring
DT1 DEVICE TRIGGER
trigger function
C0
No controller function
E1/2 Open collector driver
Codes / formats
Per IEEE 488.2
Device address
Selectable from 0 to 30 or UNL (unlist)
Max. setting rate
Approx. 40 settings per second
Max. sampling rate Approx. 15 measurements per second
U/V
U
nom
I / A
I
nom
0
0.5 I
nom
P
nom
Short-Term
Working Range
Voltage Setting
Current Setting
0.5
U
nom
Range
Range
380.5
17
14
88
221.5
Dimensions in millimeter
Pin
Designation
Function
1
SIG1 OUT
Digital, programmable, open-collector outputs (max.
30 V
/ 20 mA)
2
SIG2 OUT
3
TRG IN –
Digital, programmable control input
(low: < 1.0 V, high: 4 ... 26 V), potential-free
4
TRG IN +
5
+15 V
Auxiliary voltage, +15 V / max. 50 mA
reference point, connected to -output
6
AGND
7
U
set
–
Analog, inverting voltage control input
(0 ... –5 V correspond to 0 ... U
nom
, Ri = 10 k
)
8
U
set
+
Analog voltage control input
(0 ... +5 V correspond to 0 ... U
nom
, Ri = 10 k
)
9
I
set
+
Analog current control input
(0 ... +5 V correspond to 0 ... I
nom
, Ri = 10 k
)
10 U-MON
Output voltage measuring output
(0 ... 10 V correspond to 0 ... U
nom
, Ri = 9.8 k
)
11 I-MON
Output current measuring output
(0 ... 10 V correspond to 0 ... I
nom
, Ri = 9.4 k
)
Summary of Contents for SSP 120 Series