GMC-I Messtechnik GmbH
R2500–31
Program Entry
Press and hold simultaneously
Configuration
Display
Selection
Standard
Comment
Program selection
ProG
no. 1
Load program 1
...
no. 8
Load program 8
Put1
Save current program
to program 1
...
Put8
Save current program
to program 8
cLr
Delete current program
no. 1
Performance after reset
Auto
StoP
/
run
StoP
Valid for all 8 programs
Wait Until Setpoint is reached
wait
no
/
yes
no
Valid for all 8 programs
Type of segments
segs
ramp
/
step
Ramps/increments
rAMP
Valid for all 8 programs
Unit of time for segments
tIME
M-S
/
H-M
Seconds / minutes
M-S
Valid for all 8 programs
Duration of segment 1
MS 1
0:00 ... 99:59
0:00
Target setpoint, segment 1
SP 1
SP L
...
SPH
0°C
Control tracks, segment 1
tr 1
---- ... 21
----
Specified numbers designate active control tracks.
Duration of segment 2
MS 2
End
End of program
0:00 ... 99:59
End
If
End
is selected, no further entries are
displayed.
Target setpoint, segment 2
SP 2
SP L
...
SP H
0°C
Control tracks, segment 2
tr 2
---- ... 21
----
...
+
Summary of Contents for R2500