Computerized Control System for Square Buttonhole Machine Mode Setting
79
②
Parameter Encryption
For the steps of the parameter encryption, please
refer to “7.2 Level 1 Parameter Setting”.
Press
to quit the parameter encryption interface.
③
Check the changed parameters
When parameter is changed, the system will
display “Modified” key at parameter setting
interface
In the parameter setting interface, press
【
Modified
】
to check the changed parameters.
User can also reset the parameters here.
For the specific operation, please refer to “7.2
Level 1 Parameter Setting”
List of Level 2 Parameter
No.
Parameter
Range
Unit
Default value
K01 Pedal
Selection
D
:
Double Pedal
S-1
:
Single Pedal
(
No middle position
)
S-2
:
Single Pedal
(
With middle position
)
D
、
S-1
、
S-2
S-1
K03
Prohibition on selection of Presser type
OFF
:
Prohibit to change
ON
:
Permit to change
ON
、
OFF
ON
K04
Selection on sewing shape level
(
12/20/30
)
0~2 0
K05
Cloth cutting knife power
Set output power of cloth cutting knife
0~3 1 0