INSTALLATION GUIDELINES

Back-2-Back FreeFit to Bridges Connector

5

A

H

J

I

7

6

Summary of Contents for Free Fit

Page 1: ...tallation Manual 2019 Visit us on the Internet at globalcontract com 416 739 5000 Global Contract Inc 565 Petrolia Road North York Ontario M3J 2X8 REVISED OCTOBER 2019 ISO 9001 2015 ISO 14001 2015 ISO...

Page 2: ...2 Column Electrical 3 Column Height Adjustable Back to Back Table Feet Column Cross Beam Back to Back Crossbars and Sidebars Back to Back Bumpers Back 2 back trough BWATTC Table to Table Connector Hei...

Page 3: ...ket Adaptor Safety Glasses Allenkeys Drill with Roberson Bit Robertson Screwdriver Required Tools Warning leaflet and user manual should be left on the table after completed installation Electrical Sy...

Page 4: ...ews to adjust crossbar length Screw socket CSK UNC 5 16 18x1 Zn Do not use the two middle holes of the crossbars Adjustable crossbar Fixed crossbar Assemble the feet on the columns Tighten screws firm...

Page 5: ...pose The work top is resting on the sidebars and on self adhesive rubber bumpers placed on the crossbars The bumpers should be placed as close to the fixing screws for the work top as pos sible to kee...

Page 6: ...ews firmly IMPORTANT Do not use the two middle holes of the crossbars Do not insert any object in the two middle holes as this can damage electronic components Loosen the round headed screws on the cr...

Page 7: ...r crossbar or screws into worksurface Handset w Display The handset is mounted at the front edge of the work top screwed to the underside with screws supplied with the unit Connect cables and power su...

Page 8: ...able Back to Back Table Feet BWA2DxxxxA9 BWAG2DxxxxA9 BWA2DxxxxA8 BWAG2DxxxxA8 Assemble the feet on the columns Tighten the screws firmly IMPORTANT Make sure the correct screws are used Using too long...

Page 9: ...en STEP 2 Position the column cross beam s key hole over the preinstalled socket head screw and drive in the second socket head screw Note When the column cross beam orientation is completed one pair...

Page 10: ...optional positions The holes closest to the ends of the sidebar are dedicated for fixing the worksurface but any other available hole can be used for the same purpose Screw socket CSK UNC 1 4 20x5 8 Z...

Page 11: ...he assembly kit Wood screw round 8x3 4 Zn Wood screw CSK 10x2 3 8 Zn The shorter screws go through the sidebars The longer screws go through the crossbars Place the thin bumpers on the tube next to th...

Page 12: ...not tighten STEP 2 Drop in the trough and guide slots over the preinstalled socket head screws Note Check if the installation calls for central shared divider If so install the divider s bottom brack...

Page 13: ...tance STEP 1 Position the table to table connector under the column cross beam and align its holes with threaded holes in the bottom of the column cross beam Secure with two supplied machine screws ST...

Page 14: ...8 Zn Column cross beam Secure the column cross beam to the columns STEP 1 Drive one Socket head screws 5 16 18 x 1 into column as illustrated Do not tighten STEP 2 Position the column cross beam s key...

Page 15: ...to adjust crossbar length Sidebars Fasten sidebars in threaded holes on top of crossbars with countersunk screws There are various types of sidebars some of which can be placed in optional positions T...

Page 16: ...izes of wood screws for the work top are included in the assembly kit Wood Screw Round 8x3 4 Zn Wood screw CSK 10x2 3 8 Zn The shorter screws through sidebars The longer screws through crossbars Bumpe...

Page 17: ...5 16 18 x 1 into the Single table column cross beam as illustrated Do not tighten STEP 2 Drop in the single sided trough and guide slots over the preinstalled socket head screws STEP 3 Tighten all so...

Page 18: ...and interconnecting trough bridges had been installed and their position nalized STEP 1 Remove bottom trough channel STEP 2 Align screw ports on ceiling feed pole extrusion with holes in the trough b...

Page 19: ...d cover in place A connect Base feed s connector to adjacent power distribution Module B Tuck in the data cable bundle so that it enters the cover through the front bottom hole and exits through the t...

Page 20: ...Holder Access Door Modules GAADGDH GAADCTDH GAADCTPDDH STEP 1 Insert two device holder tabs into the cutouts of the Access door STEP 2 Rotate the device holder 90 clock wise STEP 3 Ensure that the Ddv...

Page 21: ...r distribution components STEP 1 Verify your worksurfaces and specify the location of the access door if at all and if so then left or right location STEP 2 Align the pilot holes of the worksurface wi...

Page 22: ...the cable snake by driving two countersunk screws into the steel bracket Slide in the cable snake s end segment STEP 2 Slide the steel bracket at the end of the cable snake into the notches in the po...

Page 23: ...Cable trough cover set consists of a non handed interchangeable short and long covers Their respective locations are governed by the position of the cable snake STEP 1 Align the protruding tabs with...

Page 24: ...e of the door at this con guration which offers the most ef cient way of managing cables and utilizing their available length STEP 1 Align the holes in the PC holder with the pilot holes to the dinner...

Page 25: ...DH STEP 1 Orient the cable tray so that the rectangular data plate cutout A faces front of the table STEP 2 Align the cable tray tab holes with pilot holes into the workspace STEP 3 Correctly seated c...

Page 26: ...ble Tray STEP 1 Insert the two supplied elastic O rings into the cutouts of the cable tray STEP 2 Thread the power bar through the O rings STEP 3 Adjust the elastic O rings so that they do not obstruc...

Page 27: ...nsert a pin into the cap hole and tighten it Align the table mounted framed divider brackets with inserts in the divider Note The reinforced side of the bracket faces outside STEP 4 Secure each bracke...

Page 28: ...note that if the bracket s direction is off set both brackets should be inwardly inset as illustrated STEP 2 Secure each bracket with the supplied screws FreeFit Stationary framed divider requires ded...

Page 29: ...bilize the dividers STEP 7 Ensure that the worksurfaces are parallel to each other with a precise 4 500 gap between the rear edges If not then adjust the worksurface s position on the table s structur...

Page 30: ...re parallel to each other with a precise 4 500 gap between the rear edges If not then adjust the worksurface s position on the table s structure Do not proceed unless both worksurfaces are installed c...

Page 31: ...extrusion STEP 10 Secure all four top brackets to work surfaces Note TEST THE FINAL ASSEMBLY Ride either work surface up and down its entire height adjustment range If the table frame structure is cor...

Page 32: ...n Note FreeFit single table dividers 72 wide are provided with three brackets STEP 3 Align the notch in the FreeFit Single table parallel divider bracket with the outside rear edge of the work surface...

Page 33: ...and evenly inserted into the extrusion along its full length STEP 6 Secure the top corner of felt pieces together with the supplied anodized caps STEP 7 Install mounting bracket to either side of Free...

Page 34: ...ews C of the trough brackets B underneath the Bridges table where the connector A is to be placed STEP 3 Slide the connector A between the trough brackets B and the trough D Push the connector A outwa...

Page 35: ...Page globalcontract com 34 GLOBALContract August 2018 INSTALLATION GUIDELINES Back 2 Back FreeFit to Bridges Connector 5 A H J I 7 6...

Page 36: ...Page globalcontract com 35 August 2018 GLOBALContract INSTALLATION GUIDELINES Back 2 Back FreeFit to Bridges Connector Finished Assembly...

Page 37: ...the desk to a predefined height To set the predefined height To set the predefined height for a button and or or or or Press and hold the Up and Down buttons at the same time Adjust the table to the p...

Page 38: ...ped at the limit release the down button Then press and hold the down button for more than three seconds and the desk will start to move down To clear an lower limit move the desk to the lowest possib...

Page 39: ...ic Centimeter Height Reading M Flow Visual Installation Connect Button Guide Symbol Guide Start Up Attach the handset to the underside of the table top using the two provides screws If the worksurface...

Page 40: ...sition the desk will stop at the preset height Release the button immediately press the Up or Down but ton to store the current height as a quick memory position to the selected button Press the M but...

Page 41: ...t value and return to Menu by press ing the M button Select value and return to Menu by press ing the M button Press and hold M button for at least 8 seconds until three dashes are displayed Press and...

Page 42: ...pressing the M button Select by pressing the M button Return to Menu by pressing the M button Activate Reset Homing by pressuring the Down button Navigate with the Up or Down button to the error numbe...

Page 43: ...essing the M button Return to Menu by pressing the M button navigate with the Up or Down button to see the oldest Firmware Version Software Version Displayed Press and hold M button for at least 8 sec...

Page 44: ...T5J 0X6 TEL 780 443 3913 CALGARY SHOWROOM 302 8 Avenue SE Calgary AB T2G 2M3 TEL 403 250 7770 WINNIPEG SHOWROOM 220 111 Lombard Avenue Winnipeg MB R3B 0T4 TEL 204 925 3350 OTTAWA SHOWROOM 251 Laurier...