Instruction Manual ZS100T, ZS150T & ZS200T Series II (MAM-870) Senator Industrial Air Compressors
11
Chapter 2 Installation
2.1 Outline Dimensions
Model
A
B
C
D
E
F
ZS100T
1,730
700
1,220
280
305
1″
BSP
ZS150T
1,800
760
1,400
310
357
1″
BSP
ZS200T
1,800
760
1,400
310
357
1″
BSP
Fig. 2.1 Outline Dimensions of ZS100T/ZS150T/ZS200T Series II
2.2 Installation Site of Compressor
A proper installation site should be selected for the compressor. It is recommended to use
a dedicated compressor room. The installation site should meet the following
requirements:
a.
It is essential to install the compressor in an area with good lighting and sufficient
free space for unhindered operation and maintenance. The compressor should have
a distance no less than 1 m away from its surrounding walls and ceiling.
b.
Good ventilation should be provided and proper heat radiation facility should be set
to ensure that the indoor ambient temperature is not above 40°C. It is
recommended to fit the hot air duct for heat radiation. The air draft volume of fan
should be higher than the air discharge flow of the cooling fan of the compressor.
c.
The ambient air should have low relative humidity, low dust content and no acid or
alkali corrosive gas content. If the air quality fails to reach the requirement, then it