Instruction Manual M A M - 8 7 0
Senator Industrial Air Compressors
9
2.4 Calibration Set Parameters
The calibration set parameters can be reviewed in a similar manner to that described
above for the user set parameters. However, they cannot be changed without the
CALIBRATION SET PASSWORD, which is only made available upon request. It is
unlikely that any of the calibration set parameters would need to be changed during the
life of the air compressor set.
The calibration set parameters have been pre-programmed in accordance with the
following table.
PARAMETER
SET VALUE
FUNCTION
MOTOR A
TARGET
CUR
000.0A
Enter the target current value when the
compressor is running; the controller
will divide the target current value by the
sample input current value to work out
the coefficient. The target value is for
calculation only; will not be saved.
COEF.
1.000
Controller displays the current value =
sample value × COEF.
MOTOR B
TARGET
CUR
000.0A
Enter the target current value when the
compressor is running; the controller
will divide the target current value by the
sample input current value to work out
the coefficient. The target value is for
calculation only; will not be saved.
COEF.
1.000
Controller displays the current value =
sample value × COEF.
MOTOR C
TARGET
CUR
000.0A
Enter the target current value when the
compressor is running; the controller
will divide the target current value by the
sample input current value to work out
the coefficient. The target value is for
calculation only; will not be saved.
COEF.
1.000
Controller displays the current value =
sample value × COEF.