Take a moment to verify that the following items are in the box:
●
PIPETMAN M Connected pipette
●
Power Supply 5V with AC adapter and cable
●
Battery tags (qty 4)
●
Ejector tags (qty 4)
●
Tip ejector extension (P10M model only)
●
PIPETMAN® M Connected Quick Guide
Accessories
ACCESSORIES
PART NUMBER
POWER CARROUSEL: 5–position charging carrousel for single and
multichannel models
FB1001
Battery side tags (set of 4)
F807013
Ejector side tags (set of 4)
F807014
Bluetooth® USB Dongle
F807027
Chapter 3
GETTiNG STArTEd
Switch on your PIPETMAN M Connected. Press the push button to activate
the pipette. The start-up screen appears:
The pipette will do a self calibration test and the firmware
will reset the piston.
During initialization, the volume range, version of the
firmware, and the number of readjustments is displayed on
the screen (refer to
on page 24).
Your PIPETMAN M Connected is preset on PIPET
mode and is now ready to pipette (Refer to Chapter 5
PiPETTiNG JUST LikE WiTh PiPETMAN
on page 7).
PIPETMAN M Connected goes into sleep mode after five minutes of inactivity.
The display will shut off. Just press the push button to reactivate the pipette.
Your last setting and pipetting mode will appear on the screen.
●
Safety bag
●
Certificate of Conformity with
barcode sticker
●
Lubricant (except for P10M and
multichannel models)
Volume
range
Version of
firmware
Number of
readjustments
Chapter 1
iNTrOdUCTiON
Congratulations on the purchase of your PIPETMAN® M Connected, the electronic
pipette with guaranteed performance in both standard and repetitive pipetting modes.
PIPETMAN M Connected is a Bluetooth®-enabled motorized member of the
PIPETMAN® family of pipettes from Gilson, requiring virtually no pipetting forces
to aspirate and dispense samples. Combining PIPETMAN’s renowned accuracy,
precision, and robustness with user-friendly functions, PIPETMAN M Connected helps
reduce pipetting fatigue, and increase pipetting efficiency.
PIPETMAN M Connected is a unique pipette, with only two
buttons to operate the pipette and reach all menu options.
PIPETMAN M Connected features the classic PIPETMAN look
with additional functionalities:
●
intuitive interface
with five pipetting modes for a large
number of applications: forward pipetting, repetitive, mix,
reverse, and custom mode.
●
Minimal effort:
aspirate and dispense with one click of the
push button and eject tips with ease to help reduce the
risk of repetitive strain injuries (RSI).
●
Maximum comfort:
the lightweight and balanced design of PIPETMAN M
Connected offers an ergonomic design that rests comfortably in your hand as you
pipette.
●
Minimized pipetting variability:
the motorized piston allows for high reproducibility
and accuracy while pipetting.
●
increased performance
for all day pipetting comfort.
PIPETMAN M Connected is available in 20 models covering a range from 0.5 µL to 10 mL
in single channel and 0.5 µL to 1200 µL in multichannel:
Menu
button
Push
button
Chapter 1
Please contact your Gilson representative to order additional accessories.
PIPETMAN M CONNECTED SINGLE CHANNEL
Model
Part
Number
Gilson Specifications
Volume Range
Standard PIPET
Mode
REPETITIVE
Mode
P10M
F81040
0.5–10 µL
0.5–10 µL
P20M
F81041
2–20 µL
2–20 µL
P100M
F81042
5–100 µL
5–100 µL
P200M
F81043
20–200 µL
5–200 µL
P300M
F81044
20–300 µL
10–300 µL
P1200M
F81045
100–1200 µL
20–1200 µL
P5000M
F81046
500–5000 µL
100–5000 µL
P10mLM
F81047
1–10 mL
200 µL–10 mL
PIPETMAN M CONNECTED MULTICHANNEL
Model
Part
Number
Gilson Specifications
Volume Range
Standard PIPET
Mode
REPETITIVE
Mode
P8x10M
F81048
0.5–10 µL
0.5–10 µL
P12x10M
F81049
P8x20M
F81050
1–20 µL
1–20 µL
P12x20M
F81051
P8x100M
F81052
10–100 µL
5–100 µL
P12x100M
F81053
P8x200M
F81054
20–200 µL
5–200 µL
P12x200M
F81055
P8x300M
F81056
10–300 µL
10–300 µL
P12x300M
F81057
P8x1200M
F81058
50–1200 µL
50–1200 µL
P12x1200M
F81059
NOTE
PiPETMAN M Connected is provided with a minimal battery charge. Before
using your new pipette, we strongly recommend to fully charge the battery.
PiPETMAN M Connected charges 80% of its full battery capacity in less than
an hour, but it takes three hours to fully charge the battery. Please refer to
Chapter 12