background image

B

E

N

E

F

iT F
r

O

M T
h

E B
LU

E

TO

O

T

h

® C
O

N

N

E

C

TiO

N

P

iP

E

T

Ti

NG

 M

O

d

E

S

13

12

PIPETMAN® M CONNECTED 

|

 

USER’S GUIDE

PIPETTING MODES

 

PIPETMAN® M CONNECTED

Chapter 7

BENEFiT FrOM ThE BLUETOOTh® 

CONNECTiON

PIPETMAN M Connected is a smart Bluetooth®-connected pipette that stores your 

data in the cloud for you to recall. It is compatible with the Gilson Connect platform 

of apps and has the ability to be connected to a Bluetooth 4.0 smart-ready tab or 

phone or any PC equiped with Bluetooth. You can work with your smart pipette on 

any of the Gilson apps, according to your daily goals. 
PIPETMAN M Connected can be connected to the PIPETMAN M Connected Software 

and the Gilson apps either with the USB cable or using the Bluetooth connection. 

NOTE

Bluetooth specifications:

Frequency Band: 2400–2483.5 Mhz

Power Output: 0.3 dBm

Tranfer Protocols on PC via Bluetooth

1. 

Connect the Bluetooth key (part number F807027) to a USB port. (PC only, not 

required when using a tablet). 

2.  Press the push button on the pipette to switch it on and begin initialization.
3.  When initialization is complete, press the menu button on the pipette.
4.  Press and hold the push button for 2–3 seconds until the Bluetooth indicator 

lights flash and then release the push button.

Connect with Gilson Applications 

PIPETMAN M Connected opens new possibilities in protocol execution assistance and 

data acquisition through the Bluetooth connection to Gilson Application. Please visit 

www.gilson.com

 to learn more about Gilson applications. 

PipettePilot® App

Preloaded on the TRACKMAN Connected tablet, the PipettePilot app displays where 

and when to pipette in real time to prevent pipetting errors. The app also provides 

you with a report for the complete traceability of your experiment. 

PipetteScope® App

With PipetteScope, know exactly when your pipette needs to be calibrated, request a 

calibration appointment, and view service history reports, all in one location.  

With the app, gain visibility into pipette's usage analytics and get quick 

access to user's guides. Download PipetteScope for free on Google Play. 

PiPETMAN M Connected Software 

PIPETMAN M Connected Software helps you create, save, 

and transfer up to ten custom protocols into PIPETMAN M 

Connected. Download PIPETMAN M Connected Software on

 

www.gilson.com

.

CUSTOM Mode

The 

CUSTOM

 Mode enables personalized pipetting protocol creation on a PC or tablet 

for transfer to PIPETMAN M Connected through PIPETMAN M Connected Software,  

an easy-to-use software. To use this mode on a PC, the software has to be installed on it.
PIPETMAN M Connected Software is downloadable on 

www.gilson.com

. 

To install PiPETMAN M Connected Software on a PC:

1. 

 Download the PIPETMAN M Connected Software zip file and extract the installation 

files. Then choose the program corresponding to your operating system (Windows® 

32-bit or 64-bit).

2.   Double-click the installer and follow the instructions on the screen to complete the 

installation.

3.  When completed, the PIPETMAN M Connected Software icon will appear on the 

desktop of the PC if “

Create desktop shortcut” was selected.

4.   If PIPETMAN M Connected Software is not launched automatically, then double-click 

the PIPETMAN M icon on the desktop.

Once installed, the PIPETMAN M Connected Software can be run by any user on the 
installed PC or tablet.
You can then create, edit, import, or export custom up to ten personalized pipetting 
protocols, easily and rapidly. 
To create a protocol, choose tasks in PIPETMAN M Connected Software: 

 

Aspirate: 

aspirates specified volume into the tip.

 

Beep:

 makes pipette produce a beep sound while selected tasks are executed.

 

dispense:

 dispenses specified volume from the tip. 

 

dispense all: 

dispenses all remaining volume from the tip followed by a purge action. 

 

Loop: 

enables repetition of any task once or more. Tasks between Loop (start) and 

Loop (end) will be executed in sequence for the specified number of iterations.

 

Mix: 

aspirates then dispenses a specified volume one or more times.

 

Purge:

 dispenses all remaining volume from the tip followed by purging extra volume. 

 

repetitive: 

dispense liquid into a number of aliquot, where during aspiration, additional 

liquid is added and after delivery, the excess volume remains in the tip and is discarded.

 

reverse:

 handle liquid using reverse pipetting.

 

Wait: 

introduces a wait for a specified number of seconds. 

 

Wait for click:

 pauses the protocol until Push button is clicked.

In this mode, the protocols can be automatically executed, avoiding repetitive pushes on 

the button, helping to decrease risk of RSI.
To transfer a protocol to your PIPETMAN M Connected pipette, click 

Transfer custom 

protocols to pipette

 and follow the instructions on the screen.

For more information on PIPETMAN M Connected Software, refer to the 

User's Guide 

PIPETMAN M Connected Software LT801562 on 

www.gilson.com

.

Summary of Contents for F81040

Page 1: ...User s Guide EN...

Page 2: ...D 18 Tip Ejector Extension for Use with P10M 18 Personal Label Name and or Application Tag 19 GOOD LABORATORY PRACTICE FEATURES 19 General 19 Cycle Counters 19 Alarms 20 POWER MANAGEMENT 20 Battery Ch...

Page 3: ...fatigue and increase pipetting efficiency PIPETMAN M Connected is a unique pipette with only two buttons to operate the pipette and reach all menu options PIPETMAN M Connected features the classic PIP...

Page 4: ...9 10 11 12 13 14 15 16 17 18 19 Upper part Push button and volume adjustment knob Menu button direct access to all menu functions Tip ejector button Display Elastomer plug to cover the battery chargi...

Page 5: ...the tip by pressing the ejection button Your PIPETMAN M Connected is ready for the next pipetting cycle while maintaining the volume and the last settings Continue pipetting as you would with your mec...

Page 6: ...g protocol first change the pipetting speed of your pipette refer to Chapter 8 PIPETTING SPEED CONTROL on page 15 Aspiration can be done by using the standard speed by default speed 6 Dispensing shoul...

Page 7: ...nables personalized pipetting protocol creation on a PC or tablet for transfer to PIPETMAN M Connected through PIPETMAN M Connected Software an easy to use software To use this mode on a PC the softwa...

Page 8: ...pending on your application You can change aspiration speed and dispensing speed independently from very slow to very fast speed 1 speed 6 Your speed selection is memorized for each pipetting mode unt...

Page 9: ...4 5 P10mLM 5 7 4 5 P8x10M P12x10M 1 1 P8x20M P12x20M 2 3 1 P8x100M P12x100M 2 4 1 P8x200M P12x200M 2 3 1 P8x300M P12x300M 2 3 1 P8x1200M P12x1200M 2 4 2 3 Table 1 Immersion depth and wait time Mold an...

Page 10: ...surface of the liquid refer to Immersion Depth and Wait Time Table 1 on page 17 Change the tip before aspirating a different liquid sample or reagent Change the tip if a droplet remains at the end of...

Page 11: ...thium Ion battery Operation on the battery is done at user s risk only Opening the pipette voids the warranty Alarms Low battery warning Service is overdue warning refer to Chapter 15 MAINTENANCE on p...

Page 12: ...mber of readjustments carried out by this pipette NOTE Changes of service settings will reset all the service info to zero Chapter 14 CONFIGURATION Enter the menu using the menu button You will find n...

Page 13: ...tion Enter the sub menu in the same way and select the ADJUSTMENT menu The adjustment menu allows you to access the following items Standard readjustment Reset settings Standard Readjustment This menu...

Page 14: ...Chapter 21 REPLACEMENT PARTS on page 34 To access the O ring remove the tip ejector and unscrew the lower part of the tip holder You should now be able to remove the O ring from the piston Sometimes t...

Page 15: ...er 16 CLEANING AND DECONTAMINATION PIPETMAN M Connected is designed so that the parts normally in contact with contaminants can easily be cleaned and decontaminated As part of your quality system you...

Page 16: ...nents with distilled or sterile water 4 Leave the parts to dry by evaporation or wipe them with a clean lint free tissue or soft cloth 5 Lubricate the piston and reassemble the pipette according to th...

Page 17: ...e used with the recommended PIPETMAN DIAMOND Tips Under these conditions Gilson volumetric specifications in standard pipetting PIPET mode are guaranteed with a performance exceeding ISO 8655 2 recomm...

Page 18: ...22 F807022 F807022 F807022 F807022 F807022 F807022 Battery window F807005 F807005 F807005 F807005 F807005 F807005 F807005 F807005 Ejector window F807006 F807006 F807006 F807006 F807006 F807006 F807006...

Page 19: ...ture and pressure for distilled water TEMPERATURE AIR PRESSURE HPA C 800 853 907 960 1013 1067 15 1 0018 1 0018 1 0019 1 0019 1 0020 1 0020 15 5 1 0018 1 0019 1 0019 1 0020 1 0020 1 0021 16 1 0019 1 0...

Page 20: ...R IMPLIED INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND ANY WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE UNDER NO CIRCUMSTANCES SHALL GILSON BE LIABLE FOR ANY CONSEQUENTIAL PUNITIVE INDIRECT OR IN...

Page 21: ...gilson com contactus LT801594 G 2021 Gilson Inc All rights reserved...

Reviews: