60
Fryer Operation
GBF
−
35 / GBF
−
50 Fryers
4.05 Removing Waste Cooking Oil from Fryer
−
continued
1. If oil is cold, heat it to at least
200°F (93°C)
.
2. The
POWER
switch
①
must remain
[ON]
&
HEAT
switch
②
must be
[OFF]
.
For a banked system,
POWER
switch
of the main unit with the filter pan must remain
[ON]
.
3.
For banked units, this step refers to the unit with the
filter pan.
Ensure
filter pan with cover
③
are in place. Check the
FILTER PAN COUPLING
④
... hose must be properly &
securely connected at the coupling. Verify that the
DISCHARGE HOSE
valve handle
⑤
is in the
[CLOSE]
position.
2
1
3
4
5
6
4. Slowly position
Drain Valve Handle
⑥
to the
[OPEN]
position & allow oil to completely drain into the filter pan,
then return the valve handle to the
[CLOSE]
position.
IMPORTANT! When drain valve is opened, controller will issue a “DRAIN IS OPEN” error & sound the alarm.
Press the [ALARM] key to silence ... error should clear when drain is re
‐
closed.
5. After all oil has drained into
filter pan,
set the
Waste Valve handle
⑫
to the
[OPEN]
position
(vertical)
.
Waste
valve is located in unit with filter pan on banked systems
.
6. Set the
Pump Switch
⑪
to the
[PUMP]
position. Waste cooking oil will be delivered to the bulk waste
collection tank. Either visually observe oil level in filter pan, or note when pump sound changes, indicating that
filter pan has emptied. Return
PUMP
&
POWER
switches to
[OFF]
.
7. Return the
Waste Valve handle
⑫
to the
[CLOSE]
position.
12
Continued on Next Page
The next steps require that cooking oil
be drained into the filter pan, exposing
the heating elements. Although fryer has safety interlocks
which disable heating elements anytime drain valve is
opened, always place HEAT switch to [OFF] prior to
draining, as a further safeguard. NEVER USE THE DRAIN
VALVE AS AN “ON/OFF HEAT
SWITCH”
.
For multi
well banked units,
DO NOT
drain more than
one (1) vat
at a time into the filter
pan!
The pan capacity is for ONLY one (1) vat of oil.
Never disconnect & attempt to remove
the filter pan from the cabinet while it contains cooking oil.
NOTE: The pump system is equipped with a pressure sensor & switch. Should a condition create excessive
back
pressure (clog, full collection tank, etc.), the pump will shutdown to prevent possible damage. Should
this occur, cease pump operation & have maintenance personnel inspect the system.
Summary of Contents for GBF-35
Page 10: ...4 ...
Page 22: ...16 Overview GBF 35 GBF 50 Fryers 3 01 Baskets Optional Auto Basket Lifts 2 Hidden 1 4 3 ...
Page 34: ...28 Overview GBF 35 GBF 50 Fryers Notes ...
Page 68: ...62 Fryer Operation GBF 35 GBF 50 Fryers ...
Page 78: ...72 Troubleshooting GBF 50 Fryer ...
Page 100: ...94 Parts List GBF 35 GBF 50 Fryers 7 12 Filter Pan 3 1 5 4 2 9 7 10 6 8 A ...
Page 102: ...96 Parts List GBF 35 GBF 50 Fryers Notes ...
Page 103: ......