28
Phones
Gigaset T300 PRO / Gigaset T500 PRO / EN Master / A31008-M2212-R102-1y-7619 / admin_administration.fm / 02.12.2010
V
e
rsion 2, 06.0
8
.2010
¤
Click on
Save
to copy your configuration to the list of phone types.
In future, you can click on
H
in the dropdown list for device types to open it for editing
purposes.
insecure
very
- if the host is already registered, it can instigate calls without hav-
ing to reauthenticate itself.
yes
- a peer can register himself easily with
the IP address (without specifying a specific port).
trustrpid
yes
or
no
(default value).
progressinband
yes
,
no
or
never
(default value).
promiscredir
yes
or
no
(default value).
port
The port number 5060 is the default value for the SIP protocol on the
Gigaset T300 PRO / Gigaset T500 PRO server. This value can be
replaced by a port number to be used exclusively for SIP.
qualify
Either
yes
,
no
or a specification in milliseconds. For
yes
, the server tests
every 2000 ms whether the client is still available. If the client does not
react within this timeframe, it is regarded as not available for Gigaset
T300 PRO / Gigaset T500 PRO and no other calls are forwarded to the
client.
defaultip
Standard IP address for a client; if the value
dynamic
is specified in the
host
field, the Gigaset T300 PRO / Gigaset T500 PRO will attempt to for-
ward incoming calls for a client still to be registered to this IP address.
rtptimeout
Number of seconds after which a connection is automatically termi-
nated after data traffic inactivity (RTP). This is advisable, e.g., when a
subscriber forgets to replace the receiver.
rtpholdtimeout
If
rtptimeout
does not respond during a call, then specify the maxi-
mum number of seconds for which a call may be held here. The
number must be greater than the
rtptimeout
value.
fromdomain
and
fromuser
Connections to some SIP networks require a user name and the
domain name of the server.