Actions/Checks
•
Check whether another error is also present
•
Check water supply
•
Check proper drainage via backflush line
•
Check ball valve settings
•
Check inputs via input menu
•
Check cabling
•
Check temperature switch
•
Check controller
•
Change temperature switch if necessary
•
Change LOGO! control unit if necessary
9.10
Error E08 – Backflush not possible, pumping system
Backflushing cannot take place since the signal contact is not issuing a signal.
Display
Lamp green
off
Lamp red
on
Alarm
on
The alarm can be deactivated by pressing the appropriate
button
Signal contact
open