Control terminals:
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P400
Analog 1 input function
P
The FI analog input can be used for various functions. It must be noted that only one of
the functions given below is possible at any time.
If, for example, an actual PID frequency is selected, the frequency setpoint cannot be
an analog signal. The setpoint can, e.g., be specified via a fixed frequency.
Analog functions:
Attention:
Only functions relevant to PosiCon are listed here.
47:
Ratio factor gearing
NOTE:
Further information can be found in the manual SK 500E / SK 520E,
BU0500. In addition, the function of the online changing of ratios using
analog inputs is described on Chapter 6.5 Taking into account the ratio
between master and slave genauer beschrieben.
Digital functions:
Attention:
Only functions relevant to PosiCon are listed here.
0 ... 82
[ 1 ]
42:
Approach reference point
43: Reference
point
44: Teach-In
45: Quit
Teach-In
75:
Bit 0 Position(increment)array
76:
Bit 1 Position(increment)array
77:
Bit 2 Position(increment)array
78:
Bit 3 Position(increment)array
81: Reset
Position
82:
Sync position array
NOTE:
A detailed description of digital functions can be found in manual SK 500E
/ SK 530E in the Chapter Control terminals under parameters P420 –
P425. The functions of the digital inputs are identical to the digital
functions of the analog inputs.
Permissible voltage when using digital functions: 7.5..24V.
P405
Analog 2 input function
P
0 ... 82
[ 0 ]
NOTE:
Further information can be found in the manual SK 500E /
SK
520E, BU0500.
This parameter is identical to P400.
P418
Analog 1 output function
P
Analog functions
(max. load: 5mA analog, 20mA digital)
:
NOTE:
Further information can be found in the manual SK 500E / SK 520E,
BU0500.
Digital functions:
All relay functions described in Parameter >Function Relay 1< P434 can also be
transferred via the analog output. If a condition has been fulfilled, then there will be 10V
at the output terminals. Negation of the function can be set in the parameter >Norm.
analog output< P419.
Attention:
Only functions relevant to PosiCon are listed here.
0 ... 52
[ 0 ]
34: Reference
35: End
position
36: Position
37: Absolute
position
38:
Absolute position array
39:
= Position (Comparison position)
40:
= Absolute position (Absolute comparison position)